The installation site should be selected in an area that is typical of the surrounding terrain and does not differ from the surrounding area in terms of heat and moisture exchange characteristics. There should be a natural surface '''(grass, soil)''' near the location of the remote sensors. | The installation site should be selected in an area that is typical of the surrounding terrain and does not differ from the surrounding area in terms of heat and moisture exchange characteristics. There should be a natural surface '''(grass, soil)''' near the location of the remote sensors. | ||
[[File:SOKOL-M1 1.png|center|frameless|681x681px]] | |||
For the correct operation of the precipitation, temperature, atmospheric pressure, and relative humidity sensors built into the weather station, the product should be installed at a height of '''2±0.05 m''' above the ground. | For the correct operation of the precipitation, temperature, atmospheric pressure, and relative humidity sensors built into the weather station, the product should be installed at a height of '''2±0.05 m''' above the ground. | ||
| Line 531: | Line 530: | ||
'''<u>''Note''</u>''' – ''<u>The results of measurements of basic meteorological parameters at stations make it possible to interpolate measured values at any point within a homogeneous territory with a radius of '''50 to 60 km''' (for precipitation and atmospheric phenomena – within a radius of approximately '''15 to 20 km''').</u>'' | '''<u>''Note''</u>''' – ''<u>The results of measurements of basic meteorological parameters at stations make it possible to interpolate measured values at any point within a homogeneous territory with a radius of '''50 to 60 km''' (for precipitation and atmospheric phenomena – within a radius of approximately '''15 to 20 km''').</u>'' | ||
[[File:SOKOL-M1 2.png|center|frameless|705x705px]] | |||
== '''<big>Installation at the place of operation</big>''' == | == '''<big>Installation at the place of operation</big>''' == | ||
| Line 556: | Line 556: | ||
− Secure the '''cover (5)''' with the '''screw (6)''' as shown in '''Figure 6.''' | − Secure the '''cover (5)''' with the '''screw (6)''' as shown in '''Figure 6.''' | ||
[[File:SOKOL-M1 4.png|center|frameless|700x700px]] | |||
| Line 586: | Line 587: | ||
'''<u>Note</u>''' – *The zero position of the wind vane is set when it points in the opposite direction from the front of the solar panel, so when the solar panel faces south, the zero position of the wind vane coincides with north! | '''<u>Note</u>''' – *The zero position of the wind vane is set when it points in the opposite direction from the front of the solar panel, so when the solar panel faces south, the zero position of the wind vane coincides with north! | ||
== '''<big> | == '''<big>Location and pinout of station connectors</big>''' == | ||
[[File:SOKOL-M1 6.png|center|frameless|747x747px]] | |||
'''1''' – | '''1''' – LED indicator | ||
'''2''' – | '''2''' – External power supply socket | ||
'''3''' – | '''3''' – USB connector | ||
'''4''' – | '''4''' – SIM card slot | ||
'''5''' – | '''5''' – GSM-antenna connector | ||
'''6''' – | '''6''' – RS-485 Open Wire socket for additional external sensors | ||
'''7''' – | '''7''' – Vane socket, | ||
'''8''' – | '''8''' – LoRa 433 MHz antenna connector | ||
'''9''' – | '''9''' – RS-485 MODBUS ‘Mbs’ socket | ||
'''10''' – | '''10''' – ‘Iridium’modem or camera 6-pin socke | ||
'''11''' – | '''11''' – Anemometer socket | ||
'''12''' – | '''12''' – Battery circuit on/off switch | ||
'''13''' – | '''13''' – Vane attachment point | ||
'''14''' – | '''14''' – Anemometer attachment point | ||
'''<u> | '''<u>Table 5</u>''' – Power input cable | ||
{| class="wikitable" | {| class="wikitable" | ||
|''' | |'''Nr.''' | ||
|''' | |'''Wire designation''' | ||
|''' | |'''Color''' | ||
|- | |- | ||
|1 | |1 | ||
| +12 | | +12 | ||
| | |Brown | ||
|- | |- | ||
|2 | |2 | ||
|GND | |GND | ||
| | |Blue | ||
|} | |} | ||
'''<u> | '''<u>Table 6</u>''' – RS485 ModBUS RTU output cable | ||
{| class="wikitable" | {| class="wikitable" | ||
|''' | |'''Nr.''' | ||
|''' | |'''Wire designation''' | ||
|''' | |'''Color''' | ||
|- | |- | ||
|1 | |1 | ||
|A | |A | ||
| | |Yellow and green | ||
|- | |- | ||
|2 | |2 | ||
|B | |B | ||
| | |Brown | ||
|- | |- | ||
|3 | |3 | ||
|GND | |GND | ||
| | |Blue | ||
|} | |} | ||
'''<u> | '''<u>Table 7</u>''' – RS-485 Open Wire socket | ||
{| class="wikitable" | {| class="wikitable" | ||
|''' | |'''Nr.''' | ||
|''' | |'''Wire designation''' | ||
|- | |- | ||
|1 | |1 | ||
| Line 673: | Line 675: | ||
|} | |} | ||
== '''<big> | == '''<big>Mounting on a tripod, mast, bracket, and pole</big>''' == | ||
The '''SOKOL-M1''' weather station is installed on a tripod, mast, pole, or bracket as shown in '''Figure 8.''' | |||
The tripod for the '''SOKOL-M1''' weather station is not included in the delivery set and must be purchased separately. | |||
<u>'' | '''<u>''To mount the weather station on a tripod, you need to:''</u>''' | ||
1) Set up the tripod at the measurement site. The unevenness of the upper head of the tripod should not exceed 0.3 mm. Secure each leg of the tripod. | |||
'''<u> | '''<u>ATTENTION! ENSURE THAT THE TRIPOD IS STABLE.</u>''' | ||
2) Secure two MS1.70.10.02 pipe clamps (3) to the top of the tripod using U-bolts (4), washers (5), and nuts (6). | |||