TD-600: Difference between revisions
→Connection to the sensor, setup, calibration and calibration via the configurator on a PC
| Line 110: | Line 110: | ||
Если при запуске конфигуратора 2.7.1 выходит ошибка, необходимо установить [https://www.fmeter.ru/download/_ftp/other/Component_registration.zip?v=270519154504 дополнительные библиотеки майкрософт.] | Если при запуске конфигуратора 2.7.1 выходит ошибка, необходимо установить [https://www.fmeter.ru/download/_ftp/other/Component_registration.zip?v=270519154504 дополнительные библиотеки майкрософт.] | ||
After starting the installation of components, you must wait for the message that the installation is complete, this may take a long time on some computers. | |||
[[Файл:Runtimepack установлен.png]] | [[Файл:Runtimepack установлен.png]] | ||
| Line 131: | Line 131: | ||
[[Файл:Ком порты С200М и С200М2.png|900x900пкс]] | [[Файл:Ком порты С200М и С200М2.png|900x900пкс]] | ||
After connecting the inverter, the sensor to it and checking the installation of drivers with checking the com port number of the inverter it is necessary to open the configurator, select the necessary com port which we could find out in the device manager(1) and press the button '''Open port'''(2). | |||
[[Файл:Открытие порта 2.7.1.png|903x903пкс]] | [[Файл:Открытие порта 2.7.1.png|903x903пкс]] | ||
After opening the port, connect the sensor to the transmitter and click '''Search for sensors''' | |||
[[Файл:Поиск датчиков 2.7.1.png|911x911пкс]]<blockquote>The connection to the FLS should be made '''within 15 seconds after the sensor has been connected''' to power, if the sensor operating mode has been changed from RS-485 to any other. </blockquote> | [[Файл:Поиск датчиков 2.7.1.png|911x911пкс]]<blockquote>The connection to the FLS should be made '''within 15 seconds after the sensor has been connected''' to power, if the sensor operating mode has been changed from RS-485 to any other. </blockquote>After connecting the sensor, you should see this menu: | ||
[[Файл:Основные параметры TD-600 2.7.1.png|935x935пкс]] | [[Файл:Основные параметры TD-600 2.7.1.png|935x935пкс]] | ||
# | # Sensor serial number | ||
# | # Sensor firmware version (FW) | ||
# | # Current value “Empty” | ||
# | # Current value “Full” | ||
# | # Network address of the sensor being polled (This address is used for RS-485 and RS-232 mode connections) | ||
# | # Current CNT level (raw level value) of the sensor | ||
# | # Current sensor level | ||
# | # Sensor temperature | ||
# | # Current sensor operating mode | ||
# | # Additional sensor settings such as: Master mode, range (1024 il 4096), angle transmission redim. | ||
# | # Current degree of filtration | ||
== '''<big>Sensor calibration</big>''' == | == '''<big>Sensor calibration</big>''' == | ||
[[Файл:Калибровка ТД-600 в конфигураторе 2.7.1.gif]] | [[Файл:Калибровка ТД-600 в конфигураторе 2.7.1.gif]] | ||
After you have lengthened or shortened the sensor tubes - you must perform a sensor calibration procedure. | |||
To do this you need: | |||
* | * Insert the centralizer into the tubes | ||
* | * Fill the tubes with fuel (by covering the drain holes with duct tape and filling the tubes by turning the sensor upside down or immersing the sensor tubes completely in fuel) | ||
* | * Wait for CNT level to stabilize (1) | ||
* | * Click “'''Set Current level'''” (2) opposite “Full” | ||
* | * The value “'''Full'''”(3) should change to a value close to the current CNT value (1), but not equal to it, because this value is set according to the temperature compensation of the sensor | ||
[[Файл:Калибровка полного ТД-600 2.7.1.png|857x857пкс]] | [[Файл:Калибровка полного ТД-600 2.7.1.png|857x857пкс]] | ||
| Line 174: | Line 174: | ||
</gallery> | </gallery> | ||
* | * Empty the tubes of fuel, leave the centralizer in the tubes | ||
* | * Wait for CNT to stabilize ('''1''') | ||
* | * Click “'''Set Current level'''” (2) opposite “Empty” | ||
* | * The value "'''Empty'''" (3) should change to a value close to the value of the current CNT (1), but not equal to it, since this value is set according to the temperature compensation of the sensor | ||
[[Файл:Калибровка пустого ТД-600 2.7.1.png|840x840пкс]] | [[Файл:Калибровка пустого ТД-600 2.7.1.png|840x840пкс]] | ||
* | * The sensor level should display as 1, the sensor calibration process is complete. | ||
Thus, CNT should increase as the sensor tubes fill with fuel. It should change from a value close to the Empty calibration value to the Full calibration value. | Thus, CNT should increase as the sensor tubes fill with fuel. It should change from a value close to the Empty calibration value to the Full calibration value. | ||
| Line 188: | Line 188: | ||
== '''<big>Setting the calibration value Full and Empty manually</big>''' == | == '''<big>Setting the calibration value Full and Empty manually</big>''' == | ||
We do not recommend using this functionality, but you can set the Full and Empty calibration values manually to save time when you are using sensors of the same length in the same tanks.<blockquote>'''<big>Attention!!! Setting calibration values manually will most likely increase the sensor error! We do not recommend doing this!</big>'''</blockquote> | We do not recommend using this functionality, but you can set the Full and Empty calibration values manually to save time when you are using sensors of the same length in the same tanks.<blockquote>'''<big>Attention!!! Setting calibration values manually will most likely increase the sensor error! We do not recommend doing this!</big>'''</blockquote>To do this, enter the calibration values Full and Empty of the previously calibrated sensor into the corresponding fields in the configurator and click “Set” against “Empty” and “Full” | ||
[[Файл:Ручная установка калибровок датчика 2.7.1.png|835x835пкс]] | [[Файл:Ручная установка калибровок датчика 2.7.1.png|835x835пкс]] | ||