TD-600: Difference between revisions
→Additional options
| Line 248: | Line 248: | ||
'''t_0=11;N_0=0001.0;t_1=15;N_1=02D8.0;t_2=FFFFFFBF;N_2=0025.0''' | '''t_0=11;N_0=0001.0;t_1=15;N_1=02D8.0;t_2=FFFFFFBF;N_2=0025.0''' | ||
where t_* is temperature in HEX | |||
11 | 11 is 17°C, 15 is 21°C, '''FFFFFFBF''' is a negative value, the first 6 digits can be ignored BF is 191 so the value is -65°C via the following formula x-256. | ||
N_* | N_* is level in HEX | ||
0001 | 0001 is 1, 02D8 is 728, 0025 is 37 | ||
The digit after the number means the slave number, 0 is the data of TD-600 itself, 1-7 are the slave numbers. | |||
To enable the master mode, check the '''Master mode''' checkbox and click '''Set mode'''. | |||
[[File:2.7.1 Configurator master mode.jpg|frameless|449x449px]] | [[File:2.7.1 Configurator master mode.jpg|frameless|449x449px]] | ||
To set up connection between TD-600 Master and slave sensors, check '''S1 ... S7 lines''' and enter network addresses of each slave sensor in the '''Net_Num''' field. Set an individual network address for each slave sensor in the settings of both the master and the slave itself and then click '''Set'''. | |||
[[File:2.7.1 Configurator master sensors.jpg|frameless|765x765px]] | [[File:2.7.1 Configurator master sensors.jpg|frameless|765x765px]] | ||