TD-600: Difference between revisions
→Setting the calibration value Full and Empty manually
| Line 194: | Line 194: | ||
We do not recommend using this functionality, but you can set the Full and Empty calibration values manually to save time when you are using sensors of the same length in the same tanks.<blockquote>'''<big>Attention!!! Setting calibration values manually will most likely increase the sensor error! We do not recommend doing this!</big>'''</blockquote>To do this, enter the calibration values Full and Empty of the previously calibrated sensor into the corresponding fields in the configurator and click “Set” against “Empty” and “Full” | We do not recommend using this functionality, but you can set the Full and Empty calibration values manually to save time when you are using sensors of the same length in the same tanks.<blockquote>'''<big>Attention!!! Setting calibration values manually will most likely increase the sensor error! We do not recommend doing this!</big>'''</blockquote>To do this, enter the calibration values Full and Empty of the previously calibrated sensor into the corresponding fields in the configurator and click “Set” against “Empty” and “Full” | ||
[[ | [[File:2.7.1 Manual set .jpg|frameless|835x835px]] | ||
== '''<big>Setting the mode, range and network address</big>''' == | == '''<big>Setting the mode, range and network address</big>''' == | ||
| Line 203: | Line 203: | ||
Check the desired mode and press '''Set''' (2). | Check the desired mode and press '''Set''' (2). | ||
[[ | [[File:2.7.1 Configurator mode set.jpg|frameless|835x835px]] | ||
- '''Режим RS-485''' ('''RS485 mode''') следует выбрать, когда планируется подключать к линии А и В интерфейса RS-485 терминала. Терминал должен иметь функцию опроса датчиков, например запрашивать у них информацию. Терминал должен уметь опрашивать датчики в соответствии с '''протоколом LLS'''. На датчиках с серийным номером выше '''26339 RS-485 и''' '''RS-232 работают паралельно.''' | - '''Режим RS-485''' ('''RS485 mode''') следует выбрать, когда планируется подключать к линии А и В интерфейса RS-485 терминала. Терминал должен иметь функцию опроса датчиков, например запрашивать у них информацию. Терминал должен уметь опрашивать датчики в соответствии с '''протоколом LLS'''. На датчиках с серийным номером выше '''26339 RS-485 и''' '''RS-232 работают паралельно.''' | ||
| Line 230: | Line 230: | ||
After changing the range, press “'''Set'''” (2). | After changing the range, press “'''Set'''” (2). | ||
[[ | [[File:2.7.1 Configurator range set.jpg|frameless|835x835px]] | ||
The range 1-1023 is most often used for sensors that are shorter than 1 meter. However, if it is a stationary tank with a small height, while the length and width are greater than 2-3 meters, it is better to choose the range 1-4095. | The range 1-1023 is most often used for sensors that are shorter than 1 meter. However, if it is a stationary tank with a small height, while the length and width are greater than 2-3 meters, it is better to choose the range 1-4095. | ||
| Line 238: | Line 238: | ||
The default network address of the sensor is 1; if more than one unit is installed or other LLS devices are added, the network address on the sensor may need to be changed. The network address of each sensor must also be specified in the settings of the receiving device (navigation terminal).<blockquote>'''<big>Attention!!! There cannot be two devices with the same network address on the same line; this will cause a conflict.</big>'''</blockquote>To change the network address, enter a new address in the range of 0-255, click “'''Change Network Address'''” (1), enter the new address (2), click “'''OK'''”(3), then you need to “'''Search for Sensors'''”(4), to connect to the sensor with the new address. | The default network address of the sensor is 1; if more than one unit is installed or other LLS devices are added, the network address on the sensor may need to be changed. The network address of each sensor must also be specified in the settings of the receiving device (navigation terminal).<blockquote>'''<big>Attention!!! There cannot be two devices with the same network address on the same line; this will cause a conflict.</big>'''</blockquote>To change the network address, enter a new address in the range of 0-255, click “'''Change Network Address'''” (1), enter the new address (2), click “'''OK'''”(3), then you need to “'''Search for Sensors'''”(4), to connect to the sensor with the new address. | ||
[[ | [[File:2.7.1 Configurator Network address changes.jpg|frameless|835x835px]] | ||
== '''<big>Дополнительные параметры</big>''' == | == '''<big>Дополнительные параметры</big>''' == | ||
| Line 261: | Line 261: | ||
Для включения режима мастера установите галочку на режиме '''Master mode''' и нажмите '''Установить''' | Для включения режима мастера установите галочку на режиме '''Master mode''' и нажмите '''Установить''' | ||
[[ | [[File:2.7.1 Configurator master mode.jpg|frameless|449x449px]] | ||
Для настройки соединения между ТД-600 Мастером и датчиками-слэйвами установите галчоки на '''S1 … S7 строки''' и введите сетевые адреса каждого датчика-слэйва в поле '''Net_Num''' . Установите индивидуальный сетевой адрес для каждого датчика-слэйва в настройках как Мастера, так и самого слэйва. и после нажмите '''Set.''' | Для настройки соединения между ТД-600 Мастером и датчиками-слэйвами установите галчоки на '''S1 … S7 строки''' и введите сетевые адреса каждого датчика-слэйва в поле '''Net_Num''' . Установите индивидуальный сетевой адрес для каждого датчика-слэйва в настройках как Мастера, так и самого слэйва. и после нажмите '''Set.''' | ||
[[ | [[File:2.7.1 Configurator master sensors.jpg|frameless|765x765px]] | ||
=== '''<big>Angle measurement</big>''' === | === '''<big>Angle measurement</big>''' === | ||
| Line 280: | Line 280: | ||
Press '''Horizon''' (3) to calibrate the tilt zero. | Press '''Horizon''' (3) to calibrate the tilt zero. | ||
[[ | [[File:2.7.1 Configurator angle settings.jpg|frameless|816x816px]] | ||
== '''<big>Tank calibration</big>''' == | == '''<big>Tank calibration</big>''' == | ||
| Line 286: | Line 286: | ||
Install the sensor into the tank of the installed tube in the previously drilled hole ø 30-35 mm. Make sure '''the gasket is installed''' between the sensor and the tank. After this, screw the screws from the installation kit into the previously drilled ø 3mm holes.<gallery widths="700" heights="400"> | Install the sensor into the tank of the installed tube in the previously drilled hole ø 30-35 mm. Make sure '''the gasket is installed''' between the sensor and the tank. After this, screw the screws from the installation kit into the previously drilled ø 3mm holes.<gallery widths="700" heights="400"> | ||
File:Installing the sensor inside the tank.png|'''<big>Installing the sensor inside the tank</big>''' | |||
File:Screwing the self-tapping screws.png|'''<big>Screwing the self-tapping screws</big>''' | |||
</gallery>Proceed to tank calibration. This procedure will result in a "level-liters" (or "level-gallons") table that will allow your monitoring platform to convert the level values that the sensor provides into liters/gallons that are displayed in the monitoring platform reports. | </gallery>Proceed to tank calibration. This procedure will result in a "level-liters" (or "level-gallons") table that will allow your monitoring platform to convert the level values that the sensor provides into liters/gallons that are displayed in the monitoring platform reports. | ||