TD-600: Difference between revisions
→Sensor calibration
| Line 174: | Line 174: | ||
[[File:Centralizer.png|none|thumb|512x512px|'''<big>Centralizer at the end of the tubes</big>''']] | [[File:Centralizer.png|none|thumb|512x512px|'''<big>Centralizer at the end of the tubes</big>''']] | ||
<gallery widths="350" heights="300"> | <gallery widths="350" heights="300"> | ||
File:Closing the drain holes, rotating the sensor, and filling the tubes with fuel.png|'''<big>Closing the drain holes, inverting the sensor and filling the tubes with fuel</big>''' | |||
File:Filling the tubes by immersing the sensor in fuel (drain holes open).png|'''<big>Filling the tubes by immersing the sensor in fuel (drain holes open)</big>''' | |||
</gallery> | </gallery> | ||
| Line 183: | Line 183: | ||
* The value "'''Empty'''" (3) should change to a value close to the value of the current CNT (1), but not equal to it, since this value is set according to the temperature compensation of the sensor | * The value "'''Empty'''" (3) should change to a value close to the value of the current CNT (1), but not equal to it, since this value is set according to the temperature compensation of the sensor | ||
[[ | [[File:2.7.1 configurator Full.jpg|frameless|872x872px]] | ||
* The sensor level should display as 1, the sensor calibration process is complete. | * The sensor level should display as 1, the sensor calibration process is complete. | ||
| Line 189: | Line 189: | ||
Thus, CNT should increase as the sensor tubes fill with fuel. It should change from a value close to the Empty calibration value to the Full calibration value. | Thus, CNT should increase as the sensor tubes fill with fuel. It should change from a value close to the Empty calibration value to the Full calibration value. | ||
[[ | [[File:TankEmptyFull.png|frameless|512x512px]]<blockquote>'''<big>ATTENTION! UNBLOCK THE DRAINAGE HOLES AFTER CALIBRATION!!!</big>'''</blockquote>[[File:Unblocking drain holes.png|frameless|759x759px]] | ||
== '''<big>Setting the calibration value Full and Empty manually</big>''' == | == '''<big>Setting the calibration value Full and Empty manually</big>''' == | ||