TD-500: Difference between revisions
→Calibration without fuel
| Line 435: | Line 435: | ||
* If such a request does not appear and the sensor is not detected, try connecting additional power to the sensor according to the connection diagram, also check that the power indication on the converter is active and that the OTG mode is enabled on the smartphone | * If such a request does not appear and the sensor is not detected, try connecting additional power to the sensor according to the connection diagram, also check that the power indication on the converter is active and that the OTG mode is enabled on the smartphone | ||
* If, after asking for permission, you receive the error “Unable to connect the device,” this is normal. Just select the fuel level sensor again.[[Файл:Ошибка не удалось подключить устройство после запроса разрешения.png|без|мини|'''<big>Ошибка не удалось подключить устройство после запроса разрешения</big>''']] | * If, after asking for permission, you receive the error “Unable to connect the device,” this is normal. Just select the fuel level sensor again.[[Файл:Ошибка не удалось подключить устройство после запроса разрешения.png|без|мини|'''<big>Ошибка не удалось подключить устройство после запроса разрешения</big>''']] | ||
* | * If you are using a C200M inverter, you can connect an additional power supply to the inverter. To do this, you need to take a power supply for charging your smartphone with a microUSB connector and connect it to the C200M using the ADD PWR connector | ||
* | * Once connected successfully, you will see the main screen of the sensor. | ||
[[Файл:Параметры ТД-150 при подключении через мобильное приложение.png]] | [[Файл:Параметры ТД-150 при подключении через мобильное приложение.png]] | ||
# | # Sensor serial number | ||
# | # Sensor firmware version (FW) | ||
# | # Sensor temperature | ||
# | # Network address of the polled sensor (This address is used when connecting in RS485 mode) | ||
# | # Current sensor operating mode | ||
# | # Current filtration type and level | ||
# | # Current sensor level | ||
# | # Connected sensor model | ||
== '''<big>Sensor calibration</big>''' == | == '''<big>Sensor calibration</big>''' == | ||
After you have lengthened or shortened the sensor tubes, you need to carry out the sensor calibration procedure. | |||
To do this you need: | |||
* Перейти в меню "'''Настройки'''" | * Перейти в меню "'''Настройки'''" | ||