Jump to content

TD-BLE: Difference between revisions

405 bytes removed ,  2 years ago
Line 508: Line 508:


To activate this function, go to the '''Additional settings''' menu '''(1)''' and press '''Conversion to liters (2)'''.<blockquote>This function is not recommended for use if your platform supports the use of a billing table, because to edit the table on the sensor you will need to travel to the sensor, while the table on the platform can be edited remotely at any time.  </blockquote><gallery mode="nolines" widths="350" heights="750">
To activate this function, go to the '''Additional settings''' menu '''(1)''' and press '''Conversion to liters (2)'''.<blockquote>This function is not recommended for use if your platform supports the use of a billing table, because to edit the table on the sensor you will need to travel to the sensor, while the table on the platform can be edited remotely at any time.  </blockquote><gallery mode="nolines" widths="350" heights="750">
Файл:Переход в дополнительные настройки TD-BLE.png
File:Addiitonal settings page.png|alt=
Файл:Переход в меню пересчета в литры на датчике.png
File:Select recalculatee in litres.png|alt=
</gallery>After that you can activate the conversion to liters or gallons and enter the conversion table manually or by uploading a ready table file.  
</gallery>After that you can activate the conversion to liters or gallons and enter the conversion table manually or by uploading a ready table file.  


Line 517: Line 517:


To create the table manually, select Level'''(2''') or Liters'''(3''') - in this case it can be any volume unit, enter the value'''(4''') and click on the arrow'''(5'''). Then, click on the three dots icon'''(6''') and then click Save to sensor ('''7''').<gallery mode="nolines" widths="350" heights="550">
To create the table manually, select Level'''(2''') or Liters'''(3''') - in this case it can be any volume unit, enter the value'''(4''') and click on the arrow'''(5'''). Then, click on the three dots icon'''(6''') and then click Save to sensor ('''7''').<gallery mode="nolines" widths="350" heights="550">
Файл:Ручной ввод таблицы тарировки .png
File:Recalculate page.png|alt=
Файл:Сохранение таблицы тарировки в датчик.png
File:Recalculate page settings.png|alt=
</gallery>In order to import a table from the .csv file that you created earlier when calibrating the tank, click on the three dots icon (1), and then click Import from file (2). After that, find the desired file on your smartphone and click on it.  
</gallery>In order to import a table from the .csv file that you created earlier when calibrating the tank, click on the three dots icon (1), and then click Import from file (2). After that, find the desired file on your smartphone and click on it.  


Save the imported table to the sensor (3)
Save the imported table to the sensor (3)


[[Файл:Импортирование тарировочной таблицы на TD-BLE.png|693x693пкс]]
[[File:Recalculate page settings 2.png|frameless]]


= '''<big>Common problems and solutions</big>''' =
= '''<big>Common problems and solutions</big>''' =
Line 531: Line 531:


If you did this without saving the table to the sensor’s memory, the sensor will not be able to display either the level or volume in liters.<gallery widths="350" heights="600">
If you did this without saving the table to the sensor’s memory, the sensor will not be able to display either the level or volume in liters.<gallery widths="350" heights="600">
Файл:Перевод в литры выключен.png|'''Перевод в литры выключен'''
File:Recalculate disabled.png|'''Recalculate in litres is disabled'''
Файл:Перевод в литры включен.png|'''Перевод в литры включен, но таблица не была загружена в память датчика'''
File:Recalculate enabled.png|'''Recalculate in litres is enabled'''
</gallery>Another possible reason could be that the sensor has not been properly calibrated and its CNT is below the Empty calibration value. In this case, recalibrate the sensor.
</gallery>Another possible reason could be that the sensor has not been properly calibrated and its CNT is below the Empty calibration value. In this case, recalibrate the sensor.


1,060

edits