== '''<big>Plow mode</big>''' == | |||
The mode is designed for installation on the '''“plow”''' type devices of snowplows used for road clearing. In this mode the sensor will transmit information that the plow is lowered and is in working position, the algorithm of operation allows to avoid false messages about the end of work when the plow is raised when passing obstacles. | |||
'''The plow must have a significant stroke to avoid false alarms caused by road irregularities (the difference between the raised and lowered angles must be greater than the vehicle inclination on irregularities).''' | |||
[[File:Imaged 1d12 1.png|center|frameless|747x747px]] | |||
[[File:Imaged 1d 12 d1c1 .png|center|frameless|759x759px]] | |||
'''Zero''' is set in '''working position''' when the plow is lowered. The sensor crosses the '''“TOP”''' and '''“DOWN”''' boundaries as the machine moves from the travel position to the working position. When the '''“DOWN”''' angle is crossed to a lower angle, the '''“Digital output turn on”''' delay timer is started. If at the end of the '''“Digital output turn on”''' timer the current angle does not exceed the '''“DOWN”''' angle, the discrete output ('''green''') will trigger and a positive voltage will appear on it. | |||
When the '''"DOWN"''' limit is crossed in the direction of a larger angle (when the moldboard is raised), the '''"Digital output turn off"''' timer is started. If the current angle remains greater than the '''"DOWN"''' limit when the '''"Digital output turn off"''' timer expires, the discrete output will open. If the sensor crosses back the “DOWN” boundary towards a smaller angle, the running '''"Digital output turn off"''' timer is reset. | |||
If it crosses “TOP” towards a higher angle, the discrete output will open '''momentarily'''. This is done in order to get a clearer readout of the discrete outputs switching (short-term raising and lowering of the gun during obstacle avoidance and turns is avoided). | |||
To set the sensor in '''Frequency''' mode: | |||
*Place the sensor in the operating position and press '''Set zero''' | |||
*Select '''Plow''' mode | |||
*Enter the value for '''Down''', '''Top''', '''Digital output turn on''', '''Digital output turn off''' and click '''Save the parameters to device'''. | |||
*If necessary, set the '''network address''' and click '''Save the parameters to device''' again. | |||
[[File:Imagesaa d 2e12.png|center|frameless|806x806px]] | |||