Line 179: Line 179:
The operation of the purple output is described in the table:
The operation of the purple output is described in the table:
[[File:Imagecerb3b33 35t.png|center|frameless|520x520px]]
[[File:Imagecerb3b33 35t.png|center|frameless|520x520px]]
== '''<big>Bucket mode</big>''' ==
This mode is designed for use on excavators to control the bucket operating time. The angle is '''periodically''' measured and '''compared with''' the previous one, if the angle changes and the difference between the current angle and the previous angle is '''greater than the set delta''', the green output will show a voltage signaling '''a trigger'''. If the angle stops changing or the difference between the two angles is less than the set delta, then after expiration of '''digital output turn off''' the voltage on the green output will disappear.
In this mode the angle is transmitted via '''RS-48'''5 interface.
[[File:Imagef13r 23r23.png|center|frameless|812x812px]]
[[File:Imageвы 1 12у 1.png|center|frameless|768x768px]]
The parameter '''Digital output turn on''' sets the angle measurement interval, at the beginning of which the current angle value is '''memorized'''. After expiration of this delay, the new current value is read, compared with the previous value, if the difference is a certain angle, which is greater than or equal to the '''“Delta”''' value, then the green discrete output will show a positive voltage (triggering, '''“sensor in operation”'''). If the '''“sensor in operation”''' and the difference value has not exceeded the set angle, the delay for '''switching off''' is started (parameter '''Digital output turn off''') and if during this time the difference of angles does not exceed the set '''Delta''' value - the voltage on the green output disappears. This separates the working and idle time of the implement.
To set the sensor in '''Bucket''' mode:
*Place the sensor in the operating position and press '''Set zero'''
*Select '''Bucket''' mode
*Enter the value for '''Delta''', '''Digital output turn of''', '''Digital output turn off''' and click '''Save the parameters to device'''.
*If necessary, set the '''network address''' and click '''Save the parameters to device''' again.