TD-600: Difference between revisions

Line 295: Line 295:


To do this you should:
To do this you should:
* Connect sensor Make sure that the filtration is set to “No” (1). Filtration slows down the level calculation and can increase the tank calibration time.  Create an Excel table. Save it in .csv format. The first row of the table should look like this: [[Файл:Первая строчка тарировки в Excel.png]] You can also create a text file on your PC/Phone or manually record calibration
* Connect sensor Make sure that the filtration is set to “No” (1). Filtration slows down the level calculation and can increase the tank calibration time.  Create an Excel table. Save it in .csv format. The first row of the table should look like this:[[File:First line in tank calibration table Excel.png|frameless|393x393px]] You can also create a text file on your PC/Phone or manually record calibration
* Select whether calibration is performed by filling or draining. The Filling method is recommended as it is more accurate. If you select the Drain method, you cannot be sure what exact amount of fuel is in the tank and whether the tank is full or not.
* Select whether calibration is performed by filling or draining. The Filling method is recommended as it is more accurate. If you select the Drain method, you cannot be sure what exact amount of fuel is in the tank and whether the tank is full or not.
* Select portion size
* Select portion size
Line 305: Line 305:
An example of calibration by filling in portions of 10 liters and imagine that in this case there are 10 liters in the tank that cannot be removed and when the sensor is placed in the tank it immediately shows the value 115 instead of 1.
An example of calibration by filling in portions of 10 liters and imagine that in this case there are 10 liters in the tank that cannot be removed and when the sensor is placed in the tank it immediately shows the value 115 instead of 1.


[[Файл:Тарировочная таблица, уровень 115, 10 литров.png]][[Файл:Добавление первой порции в бак.png|421x421пкс]]
[[File:Tank calibration first portion.png|frameless]][[File:Adding the first portion to the tank.png|frameless|356x356px]]


You add the first portion of fuel to the tank. The level should change from 115 to some other value. If the level does not change, check the sensor drain holes. They may be blocked by electrical tape, which must be removed after the sensor has been calibrated. If the holes are blocked, the air inside the tubes will prevent fuel from getting inside the tubes.
You add the first portion of fuel to the tank. The level should change from 115 to some other value. If the level does not change, check the sensor drain holes. They may be blocked by electrical tape, which must be removed after the sensor has been calibrated. If the holes are blocked, the air inside the tubes will prevent fuel from getting inside the tubes.
1,060