TD-600: Difference between revisions
→Tank calibration
| Line 309: | Line 309: | ||
You add the first portion of fuel to the tank. The level should change from 115 to some other value. If the level does not change, check the sensor drain holes. They may be blocked by electrical tape, which must be removed after the sensor has been calibrated. If the holes are blocked, the air inside the tubes will prevent fuel from getting inside the tubes. | You add the first portion of fuel to the tank. The level should change from 115 to some other value. If the level does not change, check the sensor drain holes. They may be blocked by electrical tape, which must be removed after the sensor has been calibrated. If the holes are blocked, the air inside the tubes will prevent fuel from getting inside the tubes. | ||
[[ | [[File:Adding a second portion to the tank.png|frameless|447x447px]] | ||
Next, add the following row to your table. | Next, add the following row to your table. | ||
[[ | [[File:Wired Extended table.png|frameless]] | ||
Continue this until the tank is full. | Continue this until the tank is full. | ||
| Line 321: | Line 321: | ||
Assume that you do the tank calibration in portions of 10 liters as before. The level rises to an area with a complex shape. | Assume that you do the tank calibration in portions of 10 liters as before. The level rises to an area with a complex shape. | ||
[[ | [[File:Tank calibration complex shape.png|frameless|512x512px]] | ||
You reduce the serving size from 10 to 5 liters. And continue adding portions until you overcome the area with a complex shape. | You reduce the serving size from 10 to 5 liters. And continue adding portions until you overcome the area with a complex shape. | ||
[[ | [[File:Complex shaped tank next step.png|frameless|500x500px]] | ||
When the level is above the problem area, you can return to the original serving volume of 10 liters. | When the level is above the problem area, you can return to the original serving volume of 10 liters. | ||
| Line 331: | Line 331: | ||
Once the tank is full, you will have a calibration chart like the following example. | Once the tank is full, you will have a calibration chart like the following example. | ||
[[ | [[File:Tank is full.png|frameless]][[File:Filled tank calibration table.png|frameless]] | ||
If in your case the level does not reach 1023 or 4095 because the tank cannot be filled completely, do not worry about it. It is acceptable that your table would end up like the following example, even though the sensor range is 1-1023. | If in your case the level does not reach 1023 or 4095 because the tank cannot be filled completely, do not worry about it. It is acceptable that your table would end up like the following example, even though the sensor range is 1-1023. | ||
[[ | [[File:Table for tank that can't be filled completely.png|none|thumb|'''<big>Table for a tank that cannot be filled 100%</big>''']] | ||
The number of servings depends on the capacity of the tank. See the table with our recommendations below. | The number of servings depends on the capacity of the tank. See the table with our recommendations below. | ||
{| class="wikitable" | {| class="wikitable" | ||