TD-500: Difference between revisions
→Connection diagrams
| Line 721: | Line 721: | ||
== Connection diagrams == | == Connection diagrams == | ||
In order to connect the sensor to the GPS terminal and to the power source, use the diagram presented below. | In order to connect the sensor to the GPS terminal and to the power source, use the diagram presented below. | ||
[[ | [[File:Wired RS-485 no R.png|none|thumb|512x512px|'''<big>RS-485 connection diagram</big>''']] | ||
[[ | [[File:Wired RS-485 with R.png|none|thumb|512x512px|'''<big>RS-485 connection diagram With resistor for explosion protection certificate</big>''']] | ||
To achieve explosion safety, the sensor in any mode must be connected through a resistor and not a fuse.<blockquote>'''<big>NOT WITH THE FUSE, BUT INSTEAD OF THE FUSE</big>'''</blockquote> | To achieve explosion safety, the sensor in any mode must be connected through a resistor and not a fuse.<blockquote>'''<big>NOT WITH THE FUSE, BUT INSTEAD OF THE FUSE</big>'''</blockquote> | ||
[[ | [[File:Wired Frequency mode.png|none|thumb|512x512px|'''<big>Wiring diagram for Frequency output</big>''']] | ||
= '''<big>Sensor and cable sealing</big>''' = | = '''<big>Sensor and cable sealing</big>''' = | ||