TD-500: Difference between revisions
→Connection to the sensor, setup, calibration and calibration via the configurator on a PC
| Line 109: | Line 109: | ||
Датчик можно настроить при помощи [https://www.fmeter.ru/download/_ftp/all/dut/FLS_Configurator.zip?v=210521143455 '''<big>конфигуратора на ПК</big>'''] (далее - "'''конфигуратор'''"). | Датчик можно настроить при помощи [https://www.fmeter.ru/download/_ftp/all/dut/FLS_Configurator.zip?v=210521143455 '''<big>конфигуратора на ПК</big>'''] (далее - "'''конфигуратор'''"). | ||
'''Connect the sensor to the USB-RS-485 converter using a 6-pin MOLEX connector''' or using cable clamps if a cable route is connected to the sensor. Orange wire is line A of the RS-485 sensor interface, white wire is line B of the RS-485 sensor interface, black wire is GND, red is PWR | '''Connect the sensor to the USB-RS-485 converter using a 6-pin MOLEX connector''' or using cable clamps if a cable route is connected to the sensor. Orange wire is line A of the RS-485 sensor interface, white wire is line B of the RS-485 sensor interface, black wire is GND, red is PWR. | ||
[[ | [[File:Sensor connected via MOLEX.png|none|thumb|742x742px|'''<big>Sensor connected via MOLEX</big>''']] | ||
[[ | [[File:Sensor connected via cables and cable clamps.png|none|thumb|747x747px|'''<big>Sensor connected via cables and cable clamps</big>''']] | ||
We recommend using our Escort C200M/C200M2 USB-RS-485 converter, since we cannot guarantee 100% compatibility of our devices with converters from other brands. | We recommend using our Escort C200M/C200M2 USB-RS-485 converter, since we cannot guarantee 100% compatibility of our devices with converters from other brands. | ||
| Line 124: | Line 124: | ||
The com port number displayed in this menu is also needed to connect the sensor. | The com port number displayed in this menu is also needed to connect the sensor. | ||
[[ | [[File:Com ports connected.png|frameless|798x798px]] | ||
After connecting the converter, sensor to it and checking the installation of drivers by checking the com port number of the converter, you need to open the configurator, select the desired com port which we could find in the device manager ('''1''') and press the '''FLS''' button ('''2'''). | After connecting the converter, sensor to it and checking the installation of drivers by checking the com port number of the converter, you need to open the configurator, select the desired com port which we could find in the device manager ('''1''') and press the '''FLS''' button ('''2'''). | ||
[[ | [[File:Com ports selection.png|frameless|661x661px]]<blockquote>The connection to the FLS should be made '''within 15 seconds after the sensor has been connected''' to power, if the sensor operating mode has been changed from RS-485 to any other. </blockquote>After connecting the sensor you should see this menu: | ||
[[ | [[File:Main page PC configurator.png|frameless|685x685px]] | ||
# Sensor serial number | # Sensor serial number | ||