TD-150: Difference between revisions
→Setting the mode
| Line 217: | Line 217: | ||
Select the mode you need('''1''') and click '''“Save parameters to device”'''('''2''') | Select the mode you need('''1''') and click '''“Save parameters to device”'''('''2''') | ||
[[ | [[File:Wire mode settings.png|frameless|572x572px]] | ||
- '''Passive RS485''' should be selected when you plan to connect to line A and B of the terminal's RS-485 interface. The terminal must have the function of polling sensors, for example, requesting information from them. The terminal must be able to interrogate sensors in accordance with the '''LLS protocol'''. | - '''Passive RS485''' should be selected when you plan to connect to line A and B of the terminal's RS-485 interface. The terminal must have the function of polling sensors, for example, requesting information from them. The terminal must be able to interrogate sensors in accordance with the '''LLS protocol'''. | ||
| Line 230: | Line 230: | ||
After changing the range, click “'''Save the parameters to device'''” ('''2'''). | After changing the range, click “'''Save the parameters to device'''” ('''2'''). | ||
[[ | [[File:Wire range settings.png|frameless|561x561px]] | ||
'''The range 1-1023''' is most often used for sensors that are '''shorter than 1 meter'''. However, if we are talking about a stationary tank, the height of which is small, but the length and width are more than 2-3 m, it is better to choose the range 1-4095. | '''The range 1-1023''' is most often used for sensors that are '''shorter than 1 meter'''. However, if we are talking about a stationary tank, the height of which is small, but the length and width are more than 2-3 m, it is better to choose the range 1-4095. | ||