TD-BLE: Difference between revisions
→How and why to calibrate sensors?
| Line 127: | Line 127: | ||
[[File:Centralizer.png]] [[File:Centralizer-Centrator.png|512x512px]] | [[File:Centralizer.png]] [[File:Centralizer-Centrator.png|512x512px]] | ||
# Fill the tubes with fuel by covering the drain holes with electrical tape and turning the sensor upside down or immersing the sensor in fuel so that the fuel reaches the flange of the sensor (the drain holes are open). The first method is preferable<gallery widths="350" heights="300" mode="nolines"> | # Fill the tubes with fuel by covering the drain holes with electrical tape and turning the sensor upside down or immersing the sensor in fuel so that the fuel reaches the flange of the sensor (the drain holes are open). The first method is preferable<gallery widths="350" heights="300" mode="nolines"> | ||
File:Closing the drain holes, rotating the sensor, and filling the tubes with fuel.png|'''Closing the drain holes, rotating the sensor, and filling the tubes with fuel''' | |||
File:Filling the tubes by immersing the sensor in fuel (drain holes open).png|'''Filling the tubes by immersing the sensor in fuel (drain holes open)''' | |||
</gallery> | </gallery> | ||
# Switch the "Calibration without fuel" slider to the inactive position '''(1)''' and press the '''Full''' button '''(2)''' after the level becomes Stable or the third digit from the end stops changing (for at least 2 minutes) '''(3)'''<gallery mode="nolines" widths="300" heights="700"> | # Switch the "Calibration without fuel" slider to the inactive position '''(1)''' and press the '''Full''' button '''(2)''' after the level becomes Stable or the third digit from the end stops changing (for at least 2 minutes) '''(3)'''<gallery mode="nolines" widths="300" heights="700"> | ||