Sokol-M1+Modbus: Difference between revisions
m
no edit summary
mNo edit summary |
mNo edit summary |
||
| (One intermediate revision by the same user not shown) | |||
| Line 153: | Line 153: | ||
'''<u>01 (address) 03 (command) B4 (number of bytes – 180 or 90 registers)</u>''' | '''<u>01 (address) 03 (command) B4 (number of bytes – 180 or 90 registers)</u>''' | ||
# 82 80 – firmware (82-1.3.0) and device type + register bank number + sensor error status ( | # 82 80 – '''firmware (82-1.3.0) and device type + register bank number + sensor error status (Technical information for device developers)''' | ||
# 00 00 - the upper 16 bits of UNIX TIME | # 00 00 - the upper 16 bits of UNIX TIME | ||
# 00 00 - the lower 16 bits of UNIX TIME | # 00 00 - the lower 16 bits of UNIX TIME | ||
| Line 237: | Line 237: | ||
# 00 00 - Sokol-DS: accumulated precipitation amount, unsigned value (must be divided by 1000) | # 00 00 - Sokol-DS: accumulated precipitation amount, unsigned value (must be divided by 1000) | ||
# 00 00 - Sokol-DS; service parameters | # 00 00 - Sokol-DS; service parameters | ||
# 00 00 - | # 00 00 - (Sokol SVC1) Microwave sensor, distance to the nearest object in cm. | ||
# 00 00 - | # 00 00 - (Sokol SVC1) Microwave sensor, distance to the farthest object in cm. | ||
# 00 00 - reserve 5 | # 00 00 - reserve 5 | ||
# 00 00 - reserve 2 | # 00 00 - reserve 2 | ||
# 00 06 - black box download flags | # 00 06 - black box download flags | ||
# 01 10 - events | # 01 10 - '''events (Technical information for device developers)''' | ||
'''<u>0E 03 – CRC-16 modbus</u>''' | '''<u>0E 03 – CRC-16 modbus</u>''' | ||