TD-600: Difference between revisions

Line 871: Line 871:
If the sensor does not connect to the configurator, do the following:
If the sensor does not connect to the configurator, do the following:


* Make sure that the correct COM port number is selected and that drivers and libraries are installed (STMicroelectronics Virtual COM Port (1)(C200M) or USB-SERIAL CH341A (2)(C200M2) in the COM and LPT ports section of the Windows device manager "to enter this menu, press win+r and enter devmgmt.msc and press OK (3) and then expand the com ports submenu (4)" [[Файл:Ком порты С200М и С200М2.png|877x877пкс]] [[Файл:Выбор ком порта и ДУТ.png]]
* Make sure that the correct COM port number is selected and that drivers and libraries are installed (STMicroelectronics Virtual COM Port (1)(C200M) or USB-SERIAL CH341A (2)(C200M2) in the COM and LPT ports section of the Windows device manager "to enter this menu, press win+r and enter devmgmt.msc and press OK (3) and then expand the com ports submenu (4)"  
* [[File:Com ports connected.png|frameless|691x691px]]
* [[File:Com ports selection.png|frameless|697x697px]]
* If possible, connect another sensor that is sure to work; if it connects, then there are no problems with the COM port or converter
* If possible, connect another sensor that is sure to work; if it connects, then there are no problems with the COM port or converter


Line 888: Line 890:


For RS-485, lines A and B of the converter must be connected to lines A and B of the sensor
For RS-485, lines A and B of the converter must be connected to lines A and B of the sensor
[[Файл:Подключения для снятие лога RS-485 .png|без|мини|820x820пкс|'''<big>Подключения для снятие лога RS-485</big>''' ]]
[[File:RS-485 Logging Connections .png|none|thumb|585x585px|'''<big>RS-485 Logging Connections</big>''']]
Запустите [https://drive.google.com/file/d/10i7v4TZ9-JDJYPAh-9JSh4x6vkM93BVV/view?usp=sharing terminal.exe] и настройте СОМ порт как показано ниже:
Запустите [https://drive.google.com/file/d/10i7v4TZ9-JDJYPAh-9JSh4x6vkM93BVV/view?usp=sharing terminal.exe] и настройте СОМ порт как показано ниже:


Line 896: Line 898:


After connecting the converter correctly, select the COM port and click Connect. If the sensor is polled by the terminal and responds, then everything is in order.
After connecting the converter correctly, select the COM port and click Connect. If the sensor is polled by the terminal and responds, then everything is in order.
[[Файл:Датчик отвечает терминалу по RS-485.png|без|мини|667x667пкс|'''<big>Датчик отвечает терминалу по RS-485</big>''']]
[[File:Sensor responds to the terminal via RS-485.png|none|thumb|529x529px|'''<big>Sensor responds to the terminal via RS-485</big>''']]
If there is no communication between the two devices, try polling the sensor manually.
If there is no communication between the two devices, try polling the sensor manually.


To do this, enter the request '''31$01$06$6C''' for the sensor with network address 1 and click '''Send'''
To do this, enter the request '''31$01$06$6C''' for the sensor with network address 1 and click '''Send'''
[[Файл:Отправка запроса на датчик.png|без|мини|673x673пкс|'''<big>Отправка запроса на датчик</big>''']]
[[File:Sending a request to the sensor.png|none|thumb|528x528px|'''<big>Sending a request to the sensor</big>''']]
The structure of the request depends on the network address of the sensor. If you change the sensor address to 255, for example, then the request would look like this
The structure of the request depends on the network address of the sensor. If you change the sensor address to 255, for example, then the request would look like this


Line 910: Line 912:


In order to calculate the checksum, you can go to the '''[https://crccalc.com/ crccalc]''' website and enter your request without the '''$''' sign, select HEX, CRC-8/MAXIM and click Calc CRC-8
In order to calculate the checksum, you can go to the '''[https://crccalc.com/ crccalc]''' website and enter your request without the '''$''' sign, select HEX, CRC-8/MAXIM and click Calc CRC-8
[[Файл:Расчет CRC для адреса 255.png|без|мини|678x678пкс|'''<big>Расчет CRC для адреса 255</big>''']]
[[File:CRC calculation for address 255.png|none|thumb|595x595px|'''<big>CRC calculation for address 255</big>''']]
If the sensor is polled by the terminal and responds, then everything is in order.
If the sensor is polled by the terminal and responds, then everything is in order.