TD-600: Difference between revisions
→Preparing the sensor
| Line 90: | Line 90: | ||
H - height of the tank at the installation point.<blockquote>'''ATTENTION!!!''' '''The minimum length''' of the tubes should not be less than '''15 cm (150 mm)'''. Otherwise, it will most likely not be possible to obtain adequate graphics. The maximum length of the tubes can reach '''6m.'''</blockquote> | H - height of the tank at the installation point.<blockquote>'''ATTENTION!!!''' '''The minimum length''' of the tubes should not be less than '''15 cm (150 mm)'''. Otherwise, it will most likely not be possible to obtain adequate graphics. The maximum length of the tubes can reach '''6m.'''</blockquote> | ||
[[ | [[File:Measuring height of the tank.png|none|thumb|780x780px|'''<big>Measuring height of the tank</big>''']] | ||
[[ | [[File:Measuring tubes length.png|none|thumb|772x772px|'''<big>Measuring the length of tubes</big>''']] | ||
Use a hacksaw to cut the tubes. When sawing, be careful not to damage the connection of the tubes to the circuit board inside the sensor head and to prevent metal shavings from falling into the tubes. | Use a hacksaw to cut the tubes. When sawing, be careful not to damage the connection of the tubes to the circuit board inside the sensor head and to prevent metal shavings from falling into the tubes. | ||
[[ | [[File:Cutting the tubes.gif|none|thumb|600x600px|'''<big>Cutting the tubes</big>''']] | ||
'''Avoid getting shavings inside the tubes - this may lead to a short circuit in the sensor; if this happens, blow the tubes with compressed air through the drainage holes under the sensor flange.''' Sand the edges of the tubes with sandpaper to remove any burrs or irregularities. | '''Avoid getting shavings inside the tubes - this may lead to a short circuit in the sensor; if this happens, blow the tubes with compressed air through the drainage holes under the sensor flange.''' Sand the edges of the tubes with sandpaper to remove any burrs or irregularities. | ||
To extend sensor tubing, use a collet extension and an additional tube. | To extend sensor tubing, use a collet extension and an additional tube.Inner nuts (yellow elements) are used to connect the inner tubes. | ||
[[ | [[File:Collet connection.png|none|thumb|753x753px|'''<big>Collet connection</big>''']] | ||
Once they are installed and the studs are screwed into them, the tubes do not have to touch each other, but try to get them as close to each other as possible. | |||
[[ | [[File:Internal connection of the collet connection.png|none|thumb|748x748px|'''<big>Internal connection of the collet connection</big>''']] | ||
The outer coupling and the corresponding nuts must be securely tightened. '''The outer tubes should touch each other.''' | The outer coupling and the corresponding nuts must be securely tightened. '''The outer tubes should touch each other.''' | ||
[[ | [[File:Collet connection installed.png|none|thumb|750x750px|'''<big>Collet connection installed</big>''']] | ||
[https://www.youtube.com/watch?v=Z0HSGDMR3rQ Посмотрите это видео на нашем YouTube канале для ознакомления с соединением в реальном времени.] | [https://www.youtube.com/watch?v=Z0HSGDMR3rQ Посмотрите это видео на нашем YouTube канале для ознакомления с соединением в реальном времени.] | ||