TD-500: Difference between revisions
→Calibration without fuel
| Line 484: | Line 484: | ||
* The value "'''Empty'''" ('''4''') should change to a value close to the value of the current CNT ('''2'''), but not equal to it, since this value is set according to the temperature compensation of the sensor | * The value "'''Empty'''" ('''4''') should change to a value close to the value of the current CNT ('''2'''), but not equal to it, since this value is set according to the temperature compensation of the sensor | ||
[[ | [[File:Wired mobile settings page.png|frameless|408x408px]] | ||
Thus, '''CNT''' should increase as the sensor tubes fill with fuel. It should change from a value close to the '''Empty''' calibration value to the '''Full''' calibration value. | Thus, '''CNT''' should increase as the sensor tubes fill with fuel. It should change from a value close to the '''Empty''' calibration value to the '''Full''' calibration value. | ||
[[ | [[File:TankEmptyFull.png|frameless|512x512px]]<blockquote>'''<big>ATTENTION! UNLOCK THE DRAINAGE HOLES AFTER CALIBRATION!!!</big>'''</blockquote>[[File:Unblocking drain holes.png|frameless|670x670px]] | ||
== '''<big>Calibration without fuel</big>''' == | == '''<big>Calibration without fuel</big>''' == | ||
| Line 495: | Line 495: | ||
In this case, make sure that the sensor tubes are empty, there is no fuel in them, but the centralizer must be inserted into the tubes. Leave the "'''Calibrate without fue'''l" switch ('''1''') active ('''green''') and press "'''Calibrate'''" ('''2''') . The values above the Empty and Full buttons will change automatically. | In this case, make sure that the sensor tubes are empty, there is no fuel in them, but the centralizer must be inserted into the tubes. Leave the "'''Calibrate without fue'''l" switch ('''1''') active ('''green''') and press "'''Calibrate'''" ('''2''') . The values above the Empty and Full buttons will change automatically. | ||
[[ | [[File:Wired calibration with fuel mobile.png|frameless]] | ||
If you calibrate the sensor without fuel, the operating range may change slightly. | If you calibrate the sensor without fuel, the operating range may change slightly. | ||