TD-150-BLE: Difference between revisions
→What to do if it is not possible to completely empty the tank?
| Line 326: | Line 326: | ||
Let's assume that there are already 10 liters of fuel in the tank that cannot be removed, so when you place the sensor in the tank, it will immediately begin to show the level of 115, instead of 1.<gallery widths="400" heights="700"> | Let's assume that there are already 10 liters of fuel in the tank that cannot be removed, so when you place the sensor in the tank, it will immediately begin to show the level of 115, instead of 1.<gallery widths="400" heights="700"> | ||
File:Adding the first portion to the tank.png|'''<big>10 liters of fuel in the tank that cannot be removed</big>''' | |||
File:Calibration table with 10 liters already in the tank.jpg|'''<big>Calibration table with 10 liters already in the tank</big>''' | |||
</gallery>Next, you can add the next portion to the tank. The level value should change. If the level does not change, check the drain holes. They may be blocked by duct tape that you may have used while calibrating the sensor or by pieces of sealing compound. | </gallery>Next, you can add the next portion to the tank. The level value should change. If the level does not change, check the drain holes. They may be blocked by duct tape that you may have used while calibrating the sensor or by pieces of sealing compound. | ||
If this happens, the air trapped inside the tubes prevents the fuel from rising. | If this happens, the air trapped inside the tubes prevents the fuel from rising. | ||
[[ | [[File:Loading the table on Wialon (example). .png|none|thumb|512x512px|'''<big>Loading the table on Wialon (example). Don't forget to check “Generate XY pairs” box</big>''']] | ||
== '''<big>Tilted tank calibration with 2 FLSs</big>''' == | == '''<big>Tilted tank calibration with 2 FLSs</big>''' == | ||