We do not recommend using this functionality, but you can set the Full and Empty calibration values manually to save time when you are using sensors of the same length in the same tanks.<blockquote>'''<big>Attention!!! Setting calibration values manually will most likely increase the sensor error! We do not recommend doing this!</big>'''</blockquote>To do this, enter the Full and Empty calibration values of the previously calibrated sensor into the appropriate fields in the configurator.
We do not recommend using this functionality, but you can set the Full and Empty calibration values manually to save time when you are using sensors of the same length in the same tanks.<blockquote>'''<big>Attention!!! Setting calibration values manually will most likely increase the sensor error! We do not recommend doing this!</big>'''</blockquote>To do this, enter the Full and Empty calibration values of the previously calibrated sensor into the appropriate fields in the configurator.


[[Файл:Переход в инженерное меню конфигуратора ПК.png|727x727пкс]]
[[File:Wired advanced menu.png|frameless|678x678px]]


[[Файл:Переход в установку калибровочных значений вручную.png|688x688пкс]]
[[File:Wired advanced menu page.png|frameless|624x624px]]


[[Файл:Установка калибровочных значение вручную ПК.png|685x685пкс]]
[[File:Wired manual Empty-Full.png|frameless|623x623px]]


== '''<big>Setting the mode, range and network address</big>''' ==
== '''<big>Setting the mode, range and network address</big>''' ==
Line 531: Line 531:
Select the mode you need('''1''') and click '''“Save parameters to device”'''('''2''')
Select the mode you need('''1''') and click '''“Save parameters to device”'''('''2''')


[[Файл:Выбор режима ТД-150 ПК.png|735x735пкс]]
[[File:Wire mode settings.png|frameless|575x575px]]


- '''Passive RS485''' should be selected when you plan to connect to line A and B of the terminal's RS-485 interface. The terminal must have the function of polling sensors, for example, requesting information from them. The terminal must be able to interrogate sensors in accordance with the '''LLS protocol'''.
- '''Passive RS485''' should be selected when you plan to connect to line A and B of the terminal's RS-485 interface. The terminal must have the function of polling sensors, for example, requesting information from them. The terminal must be able to interrogate sensors in accordance with the '''LLS protocol'''.
Line 544: Line 544:
After changing the range, click “'''Save the parameters to device'''” ('''2''').
After changing the range, click “'''Save the parameters to device'''” ('''2''').


[[Файл:Установка диапазона ТД-150 ПК.png|779x779пкс]]
[[File:Wire range settings.png|frameless|584x584px]]


'''The range 1-1023''' is most often used for sensors that are '''shorter than 1 meter'''. However, if we are talking about a stationary tank, the height of which is small, but the length and width are more than 2-3 m, it is better to choose the range 1-4095.
'''The range 1-1023''' is most often used for sensors that are '''shorter than 1 meter'''. However, if we are talking about a stationary tank, the height of which is small, but the length and width are more than 2-3 m, it is better to choose the range 1-4095.
Line 550: Line 550:
=== '''<big>Setting the network address</big>''' ===
=== '''<big>Setting the network address</big>''' ===
The default network address of the sensor is 1; if more than one unit is installed or other LLS devices are added, the network address on the sensor may need to be changed. The network address of each sensor must also be specified in the settings of the receiving device (navigation terminal).<blockquote>'''<big>Attention!!! There cannot be two devices with the same network address on the same line; this will cause a conflict.</big>'''</blockquote>To change the network address, enter a new address in the range '''0-255''' in the '''“Change network address”''' field ('''1''') and click '''“Save the parameters to device”''' ('''2'''), after which the configurator should switch to the new sensor address and display the new sensor address in the field '''"Available units"''' ('''3''') and '''"Poll network address"''' ('''4''').
The default network address of the sensor is 1; if more than one unit is installed or other LLS devices are added, the network address on the sensor may need to be changed. The network address of each sensor must also be specified in the settings of the receiving device (navigation terminal).<blockquote>'''<big>Attention!!! There cannot be two devices with the same network address on the same line; this will cause a conflict.</big>'''</blockquote>To change the network address, enter a new address in the range '''0-255''' in the '''“Change network address”''' field ('''1''') and click '''“Save the parameters to device”''' ('''2'''), after which the configurator should switch to the new sensor address and display the new sensor address in the field '''"Available units"''' ('''3''') and '''"Poll network address"''' ('''4''').
[[Файл:Смена сетевого адреса ТД-150 ПК.png|без|мини|700x700пкс|'''<big>До смены сетевого адреса</big>''']]
[[File:Wired before changing Network address.png|none|thumb|635x635px|'''<big>Before changing network address</big>''']]
[[Файл:ТД-150 после смены сетевого адреса ПК.png|без|мини|701x701пкс|'''<big>После смены сетевого адреса</big>''']]
[[File:After changing network address.png|none|thumb|636x636px|'''<big>After changing network address</big>''']]


== '''<big>Tank calibration</big>''' ==
== '''<big>Tank calibration</big>''' ==