TD-150: Difference between revisions

398 bytes removed ,  1 year ago
Line 341: Line 341:


Thus, the resulting calculation tables (calibration tables) will be adequately accepted by the monitoring platform if a third FLS (virtual) is created in it, which is the sum of two real FLS.
Thus, the resulting calculation tables (calibration tables) will be adequately accepted by the monitoring platform if a third FLS (virtual) is created in it, which is the sum of two real FLS.
[[Файл:Пример_тарировочной_таблицы_ДУТ1.png|без|мини|517x517пкс|'''<big>Пример тарировочной таблицы ДУТ1</big>''']]
[[File:Tilted FLS 1.0.png|none|thumb|471x471px|'''<big>Example of FLS 1 calibration table</big>''']]
[[Файл:Пример_тарировочной_таблицы_ДУТ2.png|без|мини|450x450пкс|'''<big>Пример тарировочной таблицы ДУТ2</big>''']]
[[File:Tilted FLS 2.png|none|thumb|442x442px|'''<big>Example of FLS 2 calibration table</big>''']]


== '''<big>Calibration of a tank whose height varies along its length</big>''' ==
== '''<big>Calibration of a tank whose height varies along its length</big>''' ==
Line 354: Line 354:


    Thus, the resulting calculation tables (calibration tables) will be adequately accepted by the monitoring platform if a third FLS (virtual) is created in it, which is the sum of two real FLS.
    Thus, the resulting calculation tables (calibration tables) will be adequately accepted by the monitoring platform if a third FLS (virtual) is created in it, which is the sum of two real FLS.
[[Файл:Пример_тарировочной_таблицы_ДУТ_1.png|без|мини|632x632пкс|'''<big>Пример тарировочной таблицы ДУТ 1</big>''']]
[[File:Tilted FLS 1.png|none|thumb|'''<big>Example of FLS 1 calibration table</big>''']]
[[Файл:Пример_тарировочной_таблицы_ДУТ_2.png|без|мини|'''<big>Пример тарировочной таблицы ДУТ 2</big>''']]
[[File:Height FLS 2.png|none|thumb|'''<big>Example of FLS 2 calibration table</big>''']]


== '''<big>Filtration</big>''' ==
== '''<big>Filtration</big>''' ==
After tank calibration is completed, select the required '''“Filtration level”''' and click '''“Save the parameters to device”'''
After tank calibration is completed, select the required '''“Filtration level”''' and click '''“Save the parameters to device”'''


[[Файл:Выбор степени фильтрации ТД-150 ПК.png|700x700пкс]]
[[File:Wired Filtration.png|frameless|732x732px]]


Below are recommendations for choosing the filtration level for different types of vehicles:
Below are recommendations for choosing the filtration level for different types of vehicles:
1,060

edits