TD-150: Difference between revisions
→Preparing the sensor
| Line 63: | Line 63: | ||
Also, two or more sensors should be installed if it is not possible to install the sensor in the center of the tank and (or) the tank has an elongated shape, i.e. The length of the tank is significantly greater than its height. | Also, two or more sensors should be installed if it is not possible to install the sensor in the center of the tank and (or) the tank has an elongated shape, i.e. The length of the tank is significantly greater than its height. | ||
[[File:Two_sensors_installed_diagonally.png|none|thumb|885x885px|'''<big>Two sensors installed diagonally</big>''']] | |||
[[File: | |||
'''Note.''' Installing a single sensor in an elongated tank will allow you to detect drains and refills. But increased level fluctuations while driving may not allow the monitoring platform to correctly read fuel consumption. Therefore, installing two sensors is preferable. | '''Note.''' Installing a single sensor in an elongated tank will allow you to detect drains and refills. But increased level fluctuations while driving may not allow the monitoring platform to correctly read fuel consumption. Therefore, installing two sensors is preferable. | ||
| Line 80: | Line 79: | ||
H - height of the tank at the installation point.<blockquote>'''ATTENTION!!!''' '''The minimum length''' of the tubes should not be less than '''15 cm (150 mm)'''. Otherwise, it will most likely not be possible to obtain adequate graphics. The maximum length of the tubes can reach '''6m.'''</blockquote> | H - height of the tank at the installation point.<blockquote>'''ATTENTION!!!''' '''The minimum length''' of the tubes should not be less than '''15 cm (150 mm)'''. Otherwise, it will most likely not be possible to obtain adequate graphics. The maximum length of the tubes can reach '''6m.'''</blockquote> | ||
[[ | [[File:Measuring height of the tank.png|none|thumb|887x887px|'''<big>Measuring height of the tank</big>''']] | ||
[[ | [[File:Measuring tubes length.png|none|thumb|893x893px|'''<big>Measuring the length of tubes</big>''']] | ||
Use a hacksaw to cut the tubes. When sawing, be careful not to damage the connection of the tubes to the circuit board inside the sensor head and to prevent metal shavings from falling into the tubes. | Use a hacksaw to cut the tubes. When sawing, be careful not to damage the connection of the tubes to the circuit board inside the sensor head and to prevent metal shavings from falling into the tubes. | ||
[[ | [[File:Cutting the tubes.gif|none|thumb|600x600px|'''<big>Cutting the tubes</big>''']] | ||
'''Avoid getting shavings inside the tubes - this may lead to a short circuit in the sensor; if this happens, blow the tubes with compressed air through the drainage holes under the sensor flange.''' Sand the edges of the tubes with sandpaper to remove any burrs or irregularities. | '''Avoid getting shavings inside the tubes - this may lead to a short circuit in the sensor; if this happens, blow the tubes with compressed air through the drainage holes under the sensor flange.''' Sand the edges of the tubes with sandpaper to remove any burrs or irregularities. | ||
To extend sensor tubing, use a collet extension and an additional tube. | To extend sensor tubing, use a collet extension and an additional tube. | ||
[[ | [[File:Collet connection.png|none|thumb|749x749px|'''<big>Collet connection</big>''']] | ||
Inner nuts (yellow elements) are used to connect the inner tubes. Once they are installed and the studs are screwed into them, the tubes do not have to touch each other, but try to get them as close to each other as possible. | Inner nuts (yellow elements) are used to connect the inner tubes. Once they are installed and the studs are screwed into them, the tubes do not have to touch each other, but try to get them as close to each other as possible. | ||
[[ | [[File:Internal connection of the collet connection.png|none|thumb|748x748px|'''<big>Internal connection of the collet connection</big>''']] | ||
The outer coupling and the corresponding nuts must be securely tightened. '''The outer tubes should touch each other.''' | The outer coupling and the corresponding nuts must be securely tightened. '''The outer tubes should touch each other.''' | ||
[[ | [[File:Collet connection installed.png|none|thumb|764x764px|'''<big>Collet connection installed</big>''']] | ||
[https://www.youtube.com/watch?v=Z0HSGDMR3rQ Посмотрите это видео на нашем YouTube канале для ознакомления с соединением в реальном времени.] | [https://www.youtube.com/watch?v=Z0HSGDMR3rQ Посмотрите это видео на нашем YouTube канале для ознакомления с соединением в реальном времени.] | ||
== '''<big>Connection dimensions</big>''' == | == '''<big>Connection dimensions</big>''' == | ||
[[ | [[File:Dimenstions TD 150.png|none|thumb|702x702px|'''<big>Connection dimensions of the wired FLS</big>''']] | ||
= '''<big>Connection to the sensor, setup, calibration and calibration via [https://www.fmeter.ru/download/_ftp/all/dut/FLS_Configurator.zip?v=210521143455 the configurator on a PC]</big>''' = | = '''<big>Connection to the sensor, setup, calibration and calibration via [https://www.fmeter.ru/download/_ftp/all/dut/FLS_Configurator.zip?v=210521143455 the configurator on a PC]</big>''' = | ||