TD-Online: Difference between revisions
→Tank mounting
| Line 636: | Line 636: | ||
[[File:Filtration_effect.png|none|thumb|795x795px|'''<big>Before and after enabling filtering on the sensor</big>''']] | [[File:Filtration_effect.png|none|thumb|795x795px|'''<big>Before and after enabling filtering on the sensor</big>''']] | ||
= <big>'''Tank mounting'''</big> = | |||
The most common mounting method is self-tapping screws with a sealing washer. It is also possible to install on threaded crimp nuts, welded bushings and other structural elements. The sensor can be mounted on pre-prepared places using screws and bolts with strength class not less than 4.8. It is necessary to ensure tightness of the connection between the sensor body and the tank. For additional protection it is allowed to use automotive oil and gasoline resistant sealant. | The most common mounting method is self-tapping screws with a sealing washer. It is also possible to install on threaded crimp nuts, welded bushings and other structural elements. The sensor can be mounted on pre-prepared places using screws and bolts with strength class not less than 4.8. It is necessary to ensure tightness of the connection between the sensor body and the tank. For additional protection it is allowed to use automotive oil and gasoline resistant sealant. | ||
| Line 690: | Line 690: | ||
Take a photo of the sensor head (the sensor serial number should be visible), its tubes (the correspondence or discrepancy of the tubes length should be clearly visible), take a screenshot of the main screen of the sensor and the Settings menu page in the application and send these data to tech support. | Take a photo of the sensor head (the sensor serial number should be visible), its tubes (the correspondence or discrepancy of the tubes length should be clearly visible), take a screenshot of the main screen of the sensor and the Settings menu page in the application and send these data to tech support. | ||
== Connection losses, issues with coordinates, power supply issues == | == '''Connection losses, issues with coordinates, power supply issues''' == | ||
| Line 728: | Line 728: | ||
File:8b579a96-aea4-419e-b0d2-59ffbd2b12a5.jpg|Download complete; the file is stored in the last folder you used to create and save a tank calibration table file in | File:8b579a96-aea4-419e-b0d2-59ffbd2b12a5.jpg|Download complete; the file is stored in the last folder you used to create and save a tank calibration table file in | ||
</gallery> | </gallery> | ||
= '''<big>Firmware Update</big>''' = | |||
To update the firmware, be sure to donwload a .zip file onto your smartphone first. Do not unzip it! | |||
Then, once the sensor is connected, go to the Additional Features menu, enter the sensor's password and initiate the firmware update. You will have 30 seconds to quickly select the FW file and start the update. Otherwise, after 30 seconds, the sensor will restart and you will need to reconnect it. | |||
= '''<big>Useful links</big>''' = | = '''<big>Useful links</big>''' = | ||