TD-500: Difference between revisions
→Setting the range
| Line 226: | Line 226: | ||
* '''Frequency mode''' is used when connecting to a GPS terminal to inputs that can receive and read signals in the range '''300 Hz … 1323 Hz''' or '''300 Hz … 4395 Hz'''. | * '''Frequency mode''' is used when connecting to a GPS terminal to inputs that can receive and read signals in the range '''300 Hz … 1323 Hz''' or '''300 Hz … 4395 Hz'''. | ||
* '''Active RS485''' mode should be used if the terminal has an RS-485 connection interface, but cannot independently poll the sensor, for example, request information from it; the sensor will send its readings independently every 2 seconds. | * '''Active RS485''' mode should be used if the terminal has an RS-485 connection interface, but cannot independently poll the sensor, for example, request information from it; the sensor will send its readings independently every 2 seconds. | ||
* ''' | * '''Impulse mode''' should be used when the sensor is connected to the impulse input of the terminal. | ||
* ''' | * '''Analog mode''' is used when the sensor is connected to the analog input of the terminal (AIN), which can receive a signal from the sensor '''in the range of ≈0.2V ... ≈5.0V''' | ||
=== '''<big>Setting the range</big>''' === | === '''<big>Setting the range</big>''' === | ||
| Line 414: | Line 414: | ||
== '''<big>Connection to the sensor</big>''' == | == '''<big>Connection to the sensor</big>''' == | ||
Wired sensors can be connected to a smartphone to the [https://play.google.com/store/apps/details?id=ru.fmeter.config Escort Configurator app]. For this you will need: | |||
* Smartphone running Android operating system with OTG technology support | * Smartphone running Android operating system with OTG technology support | ||
| Line 866: | Line 866: | ||
At the moment, we know that the remote control function is supported by trackers of the Smart and Signal family produced by Navtelecom (Signal, Smart), Technocom (AvtoGRAPH) and GlonassSoft (UMKa). Transmission of commands to the sensor is possible only in RS-485 operating mode. | At the moment, we know that the remote control function is supported by trackers of the Smart and Signal family produced by Navtelecom (Signal, Smart), Technocom (AvtoGRAPH) and GlonassSoft (UMKa). Transmission of commands to the sensor is possible only in RS-485 operating mode. | ||
First you need to open the [https://www.fmeter.ru/download/_ftp/all/dut/FLS_Configurator.zip?v=210521143455 PC configurator Escort]; The converter and/or tracker must be disconnected from the computer. In the '''Service''' tab, click on the '''Remote control''' option. | |||
[[File:Remote control Settings.png|frameless|714x714px]] | [[File:Remote control Settings.png|frameless|714x714px]] | ||