TD-500: Difference between revisions

1,071 bytes removed ,  1 year ago
Line 46: Line 46:
To prepare the tank you should:
To prepare the tank you should:


* Empty the tank, clean and dry if necessary
* Empty the tank, clean and dry if necessary '''Remove fuel vapors and air from the tank''' (especially for a gasoline tank, but in the case of a diesel engine, this procedure should not be neglected, since gasoline could be added to the diesel); to do this, you can heat water to boiling point and direct the resulting steam into the tank or use carbon dioxide so that it displaces fuel vapors and air; ensure that any open flame sources are sufficiently far away from the fuel tank
* '''Remove fuel vapors and air from the tank''' (especially for a gasoline tank, but in the case of a diesel engine, this procedure should not be neglected, since gasoline could be added to the diesel); to do this, you can heat water to boiling point and direct the resulting steam into the tank or use carbon dioxide so that it displaces fuel vapors and air; ensure that any open flame sources are sufficiently far away from the fuel tank[[Файл:Удаление топливных паров.png|715x715пкс]]
* [[File:Removing fuel vapors.png|frameless|766x766px]]
* '''Find the geometric center of the tank''' '''and''' '''drill a hole''' in it using a '''ø3mm''' drill bit. Then, using a piece of stiff wire, examine the tank for the presence of partitions in it[[Файл:Выбор места установки ДУТ.png|без|мини|831x831пкс|'''<big>Выбор места установки ДУТ</big>''']][[Файл:Сверление бака и последующее исследование бака на наличие перегородок.png|без|мини|835x835пкс|'''<big>Сверление бака и последующее исследование бака на наличие перегородок</big>''']]
* '''Find the geometric center of the tank''' '''and''' '''drill a hole''' in it using a '''ø3mm''' drill bit. Then, using a piece of stiff wire, examine the tank for the presence of partitions in it
* If the space inside the tank in the selected location is free, '''drill a ø 35 mm''' hole using a bimetallic bit; When drilling, keep the bit tilted slightly to prevent the cut section from falling into the tank. Use a magnet to catch chips and prevent them from getting into the tank.[[Файл:Сверление отверстия под углом.png|без|мини|714x714пкс|'''<big>Сверление отверстия под углом</big>''']][[Файл:Удаление высверленного диска.png|без|мини|864x864пкс|'''<big>Удаление высверленного диска</big>''']]
* [[File:Choosing a location for installing the FLS.png|none|thumb|512x512px|'''<big>Choosing a location for installing the FLS</big>''']]
* [[File:Little hole drilling.png|none|thumb|512x512px|'''<big>Drilling the tank and subsequent examination of the tank for the presence of partitions</big>''']]
* If the space inside the tank in the selected location is free, '''drill a ø 35 mm''' hole using a bimetallic bit; When drilling, keep the bit tilted slightly to prevent the cut section from falling into the tank. Use a magnet to catch chips and prevent them from getting into the tank.
* [[File:Angled drilling.png|none|thumb|512x512px|'''<big>Drilling a hole at an angle</big>''']][[File:Removing metal part.png|none|thumb|512x512px|'''<big>Removing a Drilled Disc</big>''']]
* If it is impossible to install the sensor in the geometric center of the tank, try choosing another location as close as possible to the geometric center of the tank; this point should coincide with the place where the height of the tank is maximum. This way you reduce the risk and amplitude of level fluctuations associated with fuel movement while driving.
* If it is impossible to install the sensor in the geometric center of the tank, try choosing another location as close as possible to the geometric center of the tank; this point should coincide with the place where the height of the tank is maximum. This way you reduce the risk and amplitude of level fluctuations associated with fuel movement while driving.


Line 60: Line 63:


[https://youtu.be/3psA2ACmw7w?si=zQ7n_N6h0HseNdfF Видео пример важности установки датчика по геометрическому центру бака.]
[https://youtu.be/3psA2ACmw7w?si=zQ7n_N6h0HseNdfF Видео пример важности установки датчика по геометрическому центру бака.]
[[Файл:Положение датчика и перетекание топлива.png|без|мини|805x805px|<big>'''Положение датчика и перетекание топлива'''</big>]]
[[File:Sensor position and fuel flow.png|none|thumb|512x512px|'''<big>Sensor position and fuel flow</big>''']]
<blockquote>'''Attention:''' Before starting the calibration, the vehicle/fuel tank must be positioned flat in relation to the horizon, i.e. on a level surface without a slope.</blockquote>If the tank has an irregular geometric shape, the sensor must be installed at the maximum depth of the tank, closer to the geometric center.  
<blockquote>'''Attention:''' Before starting the calibration, the vehicle/fuel tank must be positioned flat in relation to the horizon, i.e. on a level surface without a slope.</blockquote>If the tank has an irregular geometric shape, the sensor must be installed at the maximum depth of the tank, closer to the geometric center.  
[[Файл:Датчик установлен в самое высокое место бака..png|без|мини|737x737пкс|'''<big>Датчик установлен в самое высокое место бака</big>''']]
[[File:The sensor is installed in the highest place of the tank.png|none|thumb|803x803px|'''<big>The sensor is installed in the highest place of the tank</big>''']]


==== '''<big>When installation in the center is impossible - two or more FLS.</big>''' ====
==== '''<big>When installation in the center is impossible - two or more FLS.</big>''' ====
Line 68: Line 71:


Also, two or more sensors should be installed if it is not possible to install the sensor in the center of the tank and (or) the tank has an elongated shape, i.e. The length of the tank is significantly greater than its height.
Also, two or more sensors should be installed if it is not possible to install the sensor in the center of the tank and (or) the tank has an elongated shape, i.e. The length of the tank is significantly greater than its height.
[[Файл:Два датчика установленных по диагонали.png|без|мини|748x748пкс|'''<big>Два датчика установленных по диагонали</big>''']]
[[File:Two sensors installed diagonally.png|none|thumb|821x821px|'''<big>Two sensors installed diagonally</big>''']]
 
'''Note.''' Installing a single sensor in an elongated tank will allow you to detect drains and refills. But increased level fluctuations while driving may not allow the monitoring platform to correctly read fuel consumption. Therefore, installing two sensors is preferable.
'''Note.''' Installing a single sensor in an elongated tank will allow you to detect drains and refills. But increased level fluctuations while driving may not allow the monitoring platform to correctly read fuel consumption. Therefore, installing two sensors is preferable.


Line 84: Line 86:


H - height of the tank at the installation point.<blockquote>'''ATTENTION!!!''' '''The minimum length''' of the tubes should not be less than '''15 cm (150 mm)'''. Otherwise, it will most likely not be possible to obtain adequate graphics. The maximum length of the tubes can reach '''6m.'''</blockquote>
H - height of the tank at the installation point.<blockquote>'''ATTENTION!!!''' '''The minimum length''' of the tubes should not be less than '''15 cm (150 mm)'''. Otherwise, it will most likely not be possible to obtain adequate graphics. The maximum length of the tubes can reach '''6m.'''</blockquote>
[[Файл:Измерение высоты бака.png|без|мини|843x843пкс|<big>'''Измерение высоты бака'''</big>]]
[[File:Measuring height of the tank.png|none|thumb|862x862px|'''<big>Measuring height of the tank</big>''']]
[[Файл:Измерение длины трубок.png|без|мини|846x846пкс|'''<big>Измерение длины трубок</big>''']]
[[File:Measuring height of the tank.png|none|thumb|860x860px|'''<big>Measuring the length of tubes</big>''']]
Use a hacksaw to cut the tubes. When sawing, be careful not to damage the connection of the tubes to the circuit board inside the sensor head and to prevent metal shavings from falling into the tubes.  
Use a hacksaw to cut the tubes. When sawing, be careful not to damage the connection of the tubes to the circuit board inside the sensor head and to prevent metal shavings from falling into the tubes.  
[[Файл:Обрезка трубок датчика.gif|без|мини|'''<big>Обрезка трубок</big>'''|600x600пкс]]
[[File:Cutting the tubes.gif|none|thumb|600x600px|'''<big>Cutting the tubes</big>''']]
'''Avoid getting shavings inside the tubes - this may lead to a short circuit in the sensor; if this happens, blow the tubes with compressed air through the drainage holes under the sensor flange.''' Sand the edges of the tubes with sandpaper to remove any burrs or irregularities.
'''Avoid getting shavings inside the tubes - this may lead to a short circuit in the sensor; if this happens, blow the tubes with compressed air through the drainage holes under the sensor flange.''' Sand the edges of the tubes with sandpaper to remove any burrs or irregularities.


To extend sensor tubing, use a collet extension and an additional tube.
To extend sensor tubing, use a collet extension and an additional tube.
[[Файл:Цанговое соединение.png|без|мини|878x878пкс|'''<big>Цанговое соединение</big>''']]
[[File:Collet connection.png|none|thumb|622x622px|'''<big>Collet connection</big>''']]
Inner nuts (yellow elements) are used to connect the inner tubes. Once they are installed and the studs are screwed into them, the tubes do not have to touch each other, but try to get them as close to each other as possible.
Inner nuts (yellow elements) are used to connect the inner tubes. Once they are installed and the studs are screwed into them, the tubes do not have to touch each other, but try to get them as close to each other as possible.
[[Файл:Внутреннее соединение цангового соединения .png|без|мини|621x621пкс|'''<big>Внутреннее соединение цангового соединения</big>''' ]]
[[File:Internal connection of the collet connection.png|none|thumb|748x748px|'''<big>Internal connection of the collet connection</big>''']]
The outer coupling and the corresponding nuts must be securely tightened. '''The outer tubes should touch each other.'''
The outer coupling and the corresponding nuts must be securely tightened. '''The outer tubes should touch each other.'''
[[Файл:Цанговое соединение установлено.png|без|мини|602x602px|'''<big>Цанговое соединение установлено</big>''']]
[[File:Collet connection installed.png|none|thumb|745x745px|'''<big>Collet connection installed</big>''']]
[https://www.youtube.com/watch?v=Z0HSGDMR3rQ Посмотрите это видео на нашем YouTube канале для ознакомления с соединением в реальном времени.]
[https://www.youtube.com/watch?v=Z0HSGDMR3rQ Посмотрите это видео на нашем YouTube канале для ознакомления с соединением в реальном времени.]


== '''<big>Connection dimensions</big>''' ==
== '''<big>Connection dimensions</big>''' ==
[[Файл:Присоединительные размеры проводных дут.png|без|мини|600x600пкс|'''<big>Присоединительные размеры проводных дут</big>''']]
[[File:Dimenstions TD 150.png|none|thumb|635x635px|'''<big>Connection dimensions of the wired FLS</big>''']]


= '''<big>Connection to the sensor, setup, calibration and calibration via [https://www.fmeter.ru/download/_ftp/all/dut/FLS_Configurator.zip?v=210521143455 the configurator on a PC]</big>''' =
= '''<big>Connection to the sensor, setup, calibration and calibration via [https://www.fmeter.ru/download/_ftp/all/dut/FLS_Configurator.zip?v=210521143455 the configurator on a PC]</big>''' =
1,060

edits