TD-150-BLE: Difference between revisions
→Tilted tank calibration with 2 FLSs
| Line 596: | Line 596: | ||
Assume that you do the tank calibration in portions of 10 liters as before. The level rises to an area with a complex shape. | Assume that you do the tank calibration in portions of 10 liters as before. The level rises to an area with a complex shape. | ||
[[ | [[File:Tank calibration complex shape.png|frameless|512x512px]] | ||
You reduce the serving size from 10 to 5 liters. And continue adding portions until you overcome the area with a complex shape. | You reduce the serving size from 10 to 5 liters. And continue adding portions until you overcome the area with a complex shape. | ||
[[ | [[File:Complex shaped tank next step.png|frameless|500x500px]] | ||
When the level is above the problem area, you can return to the original serving volume of 10 liters. | When the level is above the problem area, you can return to the original serving volume of 10 liters. | ||
| Line 606: | Line 606: | ||
Once the tank is full, you will have a calibration chart like the following example. | Once the tank is full, you will have a calibration chart like the following example. | ||
[[ | [[File:Tank is full.png|frameless|470x470px]] [[File:Filled tank calibration table.png|frameless]] | ||
If in your case the level does not reach 1023 or 4095 because the tank cannot be filled completely, do not worry about it. It is acceptable that your table would end up like the following example, even though the sensor range is 1-1023. | If in your case the level does not reach 1023 or 4095 because the tank cannot be filled completely, do not worry about it. It is acceptable that your table would end up like the following example, even though the sensor range is 1-1023. | ||
The number of servings depends on the capacity of the tank. See the table with our recommendations below. | The number of servings depends on the capacity of the tank. See the table with our recommendations below. | ||
[[ | [[File:Table for tank that can't be filled completely.png|none|thumb|'''<big>Table for a tank that cannot be filled 100%</big>''']] | ||
The number of servings depends on the capacity of the tank. See the table below for our recommendations. | The number of servings depends on the capacity of the tank. See the table below for our recommendations. | ||
{| class="wikitable" | {| class="wikitable" | ||
| Line 641: | Line 641: | ||
|} | |} | ||
<blockquote><big>The '''rule of thumb''': more portions means more accurate reports on the monitoring platform.</big></blockquote>You can create a table on your platform by loading it from a file or by entering values manually. | <blockquote><big>The '''rule of thumb''': more portions means more accurate reports on the monitoring platform.</big></blockquote>You can create a table on your platform by loading it from a file or by entering values manually. | ||
[[File:Loading the table on Wialon (example). .png|none|thumb|512x512px|'''<big>Loading the table on Wialon (example). Don't forget to check “Generate XY pairs” box</big>''']] | |||
[[ | |||
== '''<big>Tilted tank calibration with 2 FLSs</big>''' == | == '''<big>Tilted tank calibration with 2 FLSs</big>''' == | ||