TD-150: Difference between revisions

379 bytes removed ,  1 year ago
Line 746: Line 746:


<gallery widths="400" heights="400">
<gallery widths="400" heights="400">
Файл:Установка пломбы на проводной дут.png|'''<big>Installing a seal on a wired FLS</big>'''
File:Installing a seal on a wired FLS.png|'''<big>Installing a seal on a wired FLS</big>'''
Файл:Установленная пломба на проводной дут.png|'''<big>Installed seal on a wired FLS</big>'''
File:Installed seal on the wired FLS.png|'''<big>Installed seal on a wired FLS</big>'''
</gallery>To remove the seal, screw the special key from the kit into it (you can also use any self-tapping screw of a suitable size) and pull it towards you.
</gallery>To remove the seal, screw the special key from the kit into it (you can also use any self-tapping screw of a suitable size) and pull it towards you.
[[File:Removal of the seal of the wired FLS.png|none|thumb|515x515px|'''<big>Removal of the seal of the wired FLS</big>''']]
[[File:Seal after removal.png|none|thumb|'''<big>Seal after removal</big>''']]


[[Файл:Извлечение пломбы проводного дут.png|без|мини|480x480пкс|'''<big>Извлечение пломбы проводного дут</big>''']]
[[Файл:Пломба_после_извлечения.png|без|мини|'''<big>Пломба после извлечения</big>''']]
Thus, it will be impossible to remove the seal without damaging it. This provides additional protection against unauthorized access.
Thus, it will be impossible to remove the seal without damaging it. This provides additional protection against unauthorized access.


Line 757: Line 758:
Also included with the sensor of the current sample is an alternative seal if a numbered seal is required.
Also included with the sensor of the current sample is an alternative seal if a numbered seal is required.


* It is necessary to pass the cable through the hole in the sensor cover [[Файл:Альтернативная пломбировка проводного дут шаг 1.png|580x580пкс]]
* It is necessary to pass the cable through the hole in the sensor cover  
* [[File:Alternative sealing of wired FLS step 1.png|frameless|432x432px]]


* Pass both ends of the cable through the hole in the sensor head [[Файл:Альтернативная пломбировка проводного дут шаг 2.png|580x580пкс]]
* Pass both ends of the cable through the hole in the sensor head
* [[File:Alternative sealing of wired FLS step 2.png|frameless|435x435px]]


* Pass both ends through the seal, tighten the cable and install the seal by pressing on the protruding part [[Файл:Альтернативная пломбировка проводного дут шаг 3.png|750x750пкс]]
* Pass both ends through the seal, tighten the cable and install the seal by pressing on the protruding part  
* [[File:Alternative sealing of wired FLS step 3.png|frameless|555x555px]]


== '''<big>Sealing sensor of the former design</big>''' ==
== '''<big>Sealing sensor of the former design</big>''' ==
[[Файл:Пломбирование датчика в старом корпусе.png|761x761пкс]]
[[File:Sealing sensor of the former design.png|frameless|512x512px]]


== '''<big>Cable sealing</big>''' ==
== '''<big>Cable sealing</big>''' ==
To seal the sensor connector, insert a plastic seal into the special hole on the sensor connector
To seal the sensor connector, insert a plastic seal into the special hole on the sensor connector


[[Файл:Пломбирование кабеля.png]]
[[File:Wire sealing.png|frameless|493x493px]]


= '''<big>Updating the sensor firmware</big>''' =
= '''<big>Updating the sensor firmware</big>''' =
1,060

edits