Anemometer Sokol-A: Difference between revisions

From Escort Knowledge Base
(Created page with "thumb|384x384px|The current model of the '''Sokol-A''' anemorumbometer = <big>'''Definition and Purpose of Sokol-A'''</big> = The '''SOKOL-A''' anemorumbometer (hereinafter referred to as the '''Product, SOKOL-A''') is designed to remotely measure '''instantaneous, maximum, and average airflow''' '''(wind)''' '''speeds''' and '''direction''', and to transmit this data to a server (for viewing via the specialized '''Sokol Analytics so...")
 
mNo edit summary
Line 89: Line 89:




Before mounting the unit on the mast, connect the '''wind vane, anemometer''', and '''RS-485''' interface to the transducer as shown in '''Figure 8'''. '''Figure 8''' shows the connection terminals, where '''<u>1 is the terminal for connecting the wind vane</u>''', '''<u>2 is the RS-485 connection terminal,</u>''' and '''<u>3 is the terminal for connecting the anemometer.</u>'''
Before mounting the unit on the mast, connect the '''wind vane, anemometer''', and '''RS-485''' interface to the transducer as shown in '''Figure 8'''. '''Figure 8''' shows the connection terminals, where '''<u>1 is the connector for the wind vane</u>''', '''<u>2 is the RS-485 сonnector,</u>''' and '''<u>3 is the сonnector for the anemometer.</u>'''
[[File:Sokol-A pinout 2.png|center|frameless|667x667px]]
[[File:Sokol-A pinout 2.png|center|frameless|667x667px]]




'''1 -''' Подключение '''флюгера'''


'''2''' - Подключение '''RS-485'''
'''1''' - '''Wind vane connection'''


'''3''' - Подключение '''анемометра'''
'''2 -''' '''RS-485''' connection


'''3''' - '''Anemometer''' connection


'''<u>Распиновка кабеля снижения для Сокол-А:</u>'''
 
'''<u>Pinout of the extension cable for Sokol-A:</u>'''
[[File:Sokol-A pinout 3.png|center|frameless|570x570px]]
[[File:Sokol-A pinout 3.png|center|frameless|570x570px]]
Пример схемы разъемов анеморумбометра версии '''<u>Сокол-АН (зимнее исполнение)</u>''' с нагревательным элементом:
Example of the wiring diagram for the '''Sokol-AN version of the anemorumbometer (winter model)''' with a heating element:
[[File:Sokol-A pinout 4.png|center|frameless|702x702px]]
[[File:Sokol-A pinout 4.png|center|frameless|702x702px]]
'''1 -''' Подключение '''флюгера'''
'''1''' - Connecting the '''wind vane'''


'''2''' - Подключение '''анемометра'''
'''2''' - Connecting the '''anemometer'''


'''3''' - Подключение '''RS-485'''
'''3''' - Connecting the '''RS-485'''


'''4''' - Подключение питания '''нагревателя'''
'''4''' - Connecting the '''heater power supply'''




'''<u>Распиновка кабеля снижения для Сокол-АН:</u>'''
 
'''<u>Pinout of the extension cable for Sokol-AN:</u>'''
[[File:Sokol-A pinout 5.png|center|frameless|637x637px]]
[[File:Sokol-A pinout 5.png|center|frameless|637x637px]]


== '''<big>Подключение анеморумбометра к контроллеру Сокол-К1</big>''' ==
== '''<big>Connecting the anemorumbometer to the Sokol-K1 controller</big>''' ==
Подключение анеморумбометра '''Сокол–А (1)''' к контроллеру '''Сокол–К1 ТЕМГ.469413.004''' производится через кабель снижения '''М23 ТЕМГ.685631.003 (2)''', входящий в комплект поставки согласно '''<u>рисунку 19</u>'''. Подключение к контроллеру Сокол–К1 позволяет обеспечивать передачу полученных '''Анеморумбометром''' данных на расстояние '''до 8 км'''. Необходимо подключить кабель снижения в соответствующий разъем '''RS–485''' на преобразователе '''анеморумбометра''', завести кабель через '''муфту (3)''' блока '''вычислительнго (4)''' и подключить к контроллеру '''Сокол–К1 ТЕМГ.467239.004 (5)''' через разъем '''Сокол–А''' в соответствии с '''<u>рисунком 20</u>'''.
'''The Sokol-A (1)''' anemometer is connected to the '''Sokol-K1 TEMG.469413.004''' controller via the '''M23 TEMG.685631.003 (2)''' '''extension cable''', which is included in the delivery set as shown in '''Figure 19.''' Connection to the '''Sokol-K1''' controller enables the transmission of data collected by '''the anemorumbometer''' over a distance of '''up to 8 km'''. Connect the '''extension cable''' to '''the appropriate RS-485 connector''' on the '''anemorumbometer converter,''' route the cable through the cable '''coupling (3)''' of the '''computing unit (4)''', and connect it to the '''Sokol-K1 TEMG controller. 467239.004 (5)''' via the '''Sokol-A''' '''connector''' as shown in '''Figure 20.'''
[[File:Sokol-A+Sokol-K1 1.png|center|frameless|570x570px]]
[[File:Sokol-A+Sokol-K1 1.png|center|frameless|570x570px]]
[[File:Sokol-A+Sokol-K1 2.png|center|frameless|574x574px]]
[[File:Sokol-A+Sokol-K1 2.png|center|frameless|574x574px]]


== <big>'''Подключение и настройка через ПК.'''</big> ==
== <big>'''Connection and setup via a PC.'''</big> ==
Подключить измеритель можно напрямую к '''ПК.''' В случае подключения к '''ПК''' для вывода информации о направлении и скорости ветра необходимо использовать '''[https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/Sokol_Monitor.zip Sokol Analytics]''' или '''[https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/%D0%9A%D0%BE%D0%BD%D1%84%D0%B8%D0%B3%D1%83%D1%80%D0%B0%D1%82%D0%BE%D1%80%20%D0%B4%D0%BB%D1%8F%20%D0%A1%D0%9E%D0%9A%D0%9E%D0%9B-%D0%9C.zip Sokol CFG].''' Также для корректной работы программы '''Sokol CFG''' необходимо установить [https://www.fmeter.ru/download/_ftp/other/Component_registration.zip '''данный пакет системных компонентов'''], а также '''необходимую версию драйвера для вашего преобразователя RS-485, в зависимости от модели, которую вы используете'''».
You can connect the '''anemorumbometer''' directly to a '''PC.''' If you connect it to a '''PC''' to display '''wind direction and speed data''', you must use '''[https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/Sokol_Monitor.zip Sokol Analytics] or [https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/%D0%9A%D0%BE%D0%BD%D1%84%D0%B8%D0%B3%D1%83%D1%80%D0%B0%D1%82%D0%BE%D1%80%20%D0%B4%D0%BB%D1%8F%20%D0%A1%D0%9E%D0%9A%D0%9E%D0%9B-%D0%9C.zip Sokol CFG]'''. Additionally, for '''Sokol CFG''' to function properly, you must install this '''[https://www.fmeter.ru/download/_ftp/other/Component_registration.zip?v=270519154504 package of system components]''', as well as the '''appropriate driver version for your RS-485 converter, depending on the model you are using.'''


'''<u>Bolid C2000-USB - [https://bolid.ru/production/s2000-usb.html#download ссылка на скачивание драйверов.]</u>'''
'''<u>Bolid C2000-USB - [https://bolid.ru/production/s2000-usb.html#download Download link]</u>'''


'''<u>Преобразователь Эскорт C200M - [https://www.fmeter.ru/download/_ftp/escort_c-200m/%D0%94%D1%80%D0%B0%D0%B9%D0%B2%D0%B5%D1%80%20%D0%B4%D0%BB%D1%8F%20C-200M2.zip?v=150323104902 ссылка на скачивание драйверов]</u>'''
'''<u>Escort C200M converter - [https://www.fmeter.ru/download/_ftp/escort_c-200m/%D0%94%D1%80%D0%B0%D0%B9%D0%B2%D0%B5%D1%80%20%D0%B4%D0%BB%D1%8F%20C-200M2.zip?v=150323104902 Download link]</u>'''


'''<u>Преобразователь Эскорт C200M2 - [https://www.fmeter.ru/download/_ftp/escort_c-200m/%D0%94%D1%80%D0%B0%D0%B9%D0%B2%D0%B5%D1%80%20%D0%B4%D0%BB%D1%8F%20C-200M2.zip?v=150323104902 ссылка на скачивание драйверов]</u>'''
'''<u>Escort C200M2 converter - [https://www.fmeter.ru/download/_ftp/escort_c-200m/%D0%94%D1%80%D0%B0%D0%B9%D0%B2%D0%B5%D1%80%20%D0%B4%D0%BB%D1%8F%20C-200M2.zip?v=150323104902 Download link]</u>'''




Схема подключения '''Сокол–А к ПК''' изображена на '''<u>рисунках 10а и 10б</u>.''' (Преобразователь '''Эскорт С200–М2 (4)''' приобретается отдельно в случае подключения изображенного на '''<u>рисунке 10а</u>''').
The connection diagram for the '''Sokol-A to a PC''' is shown in '''Figures 10a and 10b'''. ('''The Escort C200-M2 converter (4)''' must be purchased separately for the connection shown in '''Figure 10a'''.)
[[File:Sokol-A + PC connection scheme 1.png|center|frameless|640x640px]]
[[File:Sokol-A + PC connection scheme 1.png|center|frameless|640x640px]]
[[File:Sokol-A + PC connection scheme 2.png|center|frameless|654x654px]]
[[File:Sokol-A + PC connection scheme 2.png|center|frameless|654x654px]]


== <big>'''Сокол-А + Sokol CFG'''</big> ==
== <big>'''Sokol-A + Sokol CFG'''</big> ==
Установка ПО '''[https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/%D0%9A%D0%BE%D0%BD%D1%84%D0%B8%D0%B3%D1%83%D1%80%D0%B0%D1%82%D0%BE%D1%80%20%D0%B4%D0%BB%D1%8F%20%D0%A1%D0%9E%D0%9A%D0%9E%D0%9B-%D0%9C.zip Sokol CFG]''' выполняется в следующем порядке:
Install the '''[https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/%D0%9A%D0%BE%D0%BD%D1%84%D0%B8%D0%B3%D1%83%D1%80%D0%B0%D1%82%D0%BE%D1%80%20%D0%B4%D0%BB%D1%8F%20%D0%A1%D0%9E%D0%9A%D0%9E%D0%9B-%D0%9C.zip Sokol CFG]''' software as follows:
 
− download the '''[https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/%D0%9A%D0%BE%D0%BD%D1%84%D0%B8%D0%B3%D1%83%D1%80%D0%B0%D1%82%D0%BE%D1%80%20%D0%B4%D0%BB%D1%8F%20%D0%A1%D0%9E%D0%9A%D0%9E%D0%9B-%D0%9C.zip Sokol CFG]''' software;
 
− Run the '''setup_Sokol CFG.exe file;'''


скачать специальное программное обеспечение '''[https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/%D0%9A%D0%BE%D0%BD%D1%84%D0%B8%D0%B3%D1%83%D1%80%D0%B0%D1%82%D0%BE%D1%80%20%D0%B4%D0%BB%D1%8F%20%D0%A1%D0%9E%D0%9A%D0%9E%D0%9B-%D0%9C.zip Sokol CFG]'''
Follow the '''on-screen instructions''' during installation;


запустить файл '''setup_ Sokol CFG.exe;'''
Launch the '''Sokol CFG''' software.[[File:Sokol-A + CFG 1.png|center|frameless|667x667px]]


− в процессе установки '''следовать указаниям''' на экране;


-- Запустить ПО '''Sokol CFG.'''
[[File:Sokol-A + CFG 1.png|center|frameless|667x667px]]


In the standalone software '''window,''' select '''the COM port''' to which the '''Sokol-A''' anemorumbometer is connected.


Указать в окне автономного ПО '''СОМ–порт,''' к которому подключен '''Анеморумбометр Сокол–А'''.
'''<u>If the port is not listed, follow these steps:</u>'''


'''<u>Если порт отсутствует в списке, то произвести следующие действия:</u>'''
− Open '''Device Manager''' on your computer;


перейти в диспетчер устройств вашего компьютера;
In the Ports '''(COM and LPT) section,''' open the properties of the '''<u>STMicroelectronics Virtual COM Port (C200M) or USB-SERIAL CH341A (C200M2) virtual COM port</u>''' (if there are '''no devices''' with these names in the list, '''<u>check that the driver for your converter is installed);</u>'''


в строке порты '''(СОМ и LPT)''' открыть свойства виртуального '''СОМ–порта  STMicroelectronics Virtual COM Port (С200М) или USB-SERIAL CH341A (С200М2)''' (если устройств с таким именем в списке нет, то проверить наличие установленного драйвера для вашего '''преобразователя'''»);
− '''Manually set the port''' number within the range '''COM2–COM10;'''


вручную задать номер порта в интервале '''СОМ2–СОМ10''';
− '''Restart''' the anemorumbometer by reconnecting the transducer’s USB cable to the PC; − '''Reopen''' the '''Sokol CFG''' program and select the configured COM port; − '''<u>Click the “Open Port” button.</u>'''
[[File:Device manager 2.png|center|frameless|687x687px]]


− перезагрузить '''Анеморумбометр''', переподключив '''USB–кабель преобразователя к ПК'''; − заново открыть программу '''Sokol CFG''' и выбрать установленный '''СОМ–порт;''' − нажать кнопку '''«Открыть порт».'''


После успешного подключения к '''ПО''' во вкладке '''«Датчик»''' появятся показания с датчиков '''Анеморумбометра'''. К ним относятся основные метеорологические параметры: '''направление и скорость ветра.'''
 
Once successfully connected to the '''software''', the '''"Sensors"''' tab will display '''readings''' from the anemometer. These include '''key meteorological parameters''': '''<u>wind direction and wind speed.</u>'''
[[File:Sokol-A + CFG 2.png|center|frameless|710x710px]]
[[File:Sokol-A + CFG 2.png|center|frameless|710x710px]]




'''Слева''' отображена информация о '''серийном номере и версии ПО'''.
'''The serial number and software version''' are displayed on the '''left.'''
[[File:CFG Version 1.png|center|frameless|722x722px]]
[[File:CFG Version 1.png|center|frameless|722x722px]]




Во кладке '''«Сервер»''' отображен сетевой адрес '''ModBus''' Анеморумбометра '''(поле ModBus).'''
The '''"Server"''' tab displays '''the Modbus network address''' of the anemorumbometer '''(Modbus field).'''
[[File:Sokol-A + CFG 3.png|center|frameless|726x726px]]
[[File:Sokol-A + CFG 3.png|center|frameless|726x726px]]


== '''<big>Сокол-А + Sokol Analytics</big>''' ==
== '''<big>Sokol-A + Sokol Analytics</big>''' ==
Работа с автономным [https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/Sokol_Monitor.zip '''ПО Sokol Analytics'''] выполняется в следующем порядке:
To use the standalone  [https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/Sokol_Monitor.zip '''Sokol Analytics'''] software, follow these steps:


скачать специальное программное обеспечение  [https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/Sokol_Monitor.zip '''ПО Sokol Analytics'''];
'''Download''' the [https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/Sokol_Monitor.zip '''Sokol Analytics'''] software;


запустить файл '''sokolanalytics_262c.exe''';
Run the '''sokolanalytics_262c.exe file;'''


в процессе установки следовать указаниям на экране. Запустить [https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/Sokol_Monitor.zip '''ПО Sokol Analytics'''], после чего откроется окно.
Follow the on-screen instructions during installation. Launch the [https://www.fmeter.ru/download/_ftp/meteo-kontrol/sokol-m/Sokol_Monitor.zip '''Sokol Analytics'''] software, and a '''window will open.'''
[[File:Analytics Sokol-A 1.png|center|frameless|741x741px]]
[[File:Сокол-А Analytics 12.png|center|frameless|741x741px]]




В данном окне нажмите на кнопку '''"Подключение"''' и '''"Включите"''' опрос устройства '''Sokol-A.'''
[[File:Analytics Sokol-A 2.png|center|frameless|754x754px]]


In this '''window''', click the '''"Connect"''' button and enable '''polling for the Sokol-A device'''.
[[File:Сокол-А Analytics 13.png|center|frameless|754x754px]]


Далее откроется окно опроса устройства '''Сокол-А'''. Необходимо будет произвести <u>'''настройку опроса'''.</u>


- Выбрать корректный '''COM порт''', который был назначен для вашего преобразователя.


- Установить необходимый '''сетевой адрес''' для опроса '''Сокол-А'''. Сетевой адрес '''Сокол-А''' можно '''установить/изменить/проверить''' в программе '''Sokol CFG'''. По умолчанию на анеморумбометре '''Сокол-А''' установлен '''1ый сетевой адрес.'''


- Установить необходимый '''период опроса.'''
Next, the '''Sokol-A device polling window will open.''' You will need to '''configure the polling settings.'''


- '''Включить/отключить''' автостарт опроса при запуске программы '''Sokol Analytics.'''<blockquote>
- Select the correct '''COM port''' assigned to '''your converter.'''


- Set the '''required network address''' for polling the '''Sokol-A.''' The '''Sokol-A network''' address can be set, changed, or checked in the '''Sokol CFG program'''. '''<u>By default, the Sokol-A anemometer is set to network address 1.</u>'''


'''<u>''Внимание! После изменения сетевого адреса на анеморумбометре «Сокол-А» в программе Sokol CFG визуальное отображение номера сетевого адреса может не измениться, однако фактически изменение настройки вступит в силу.''</u>'''</blockquote>
- '''Set the required''' polling interval.
[[File:Analytics Sokol-A 3.png|center|frameless|730x730px]]
 
[[File:Analytics Sokol-A 4.png|center|frameless|744x744px]]
- '''Enable/disable''' the '''automatic''' launch of the survey when '''Sokol Analytics starts.'''<blockquote>
После настройки опроса вам необходимо '''<u>сохранить изменения</u>'''. Далее вы вернётесь к основному окну опроса '''Сокол-А'''. На этом этапе вы можете перевести ползунок в '''положение ON''' для запуска опроса анеморумбометра '''Сокол-А'''.
 
 
'''<u>''Important! After changing the network address on the "Sokol-A" anemometer in the Sokol CFG program, the displayed network address may not update, but the change will take effect.''</u>'''</blockquote>
[[File:Сокол-А Analytics 14.png|center|frameless|730x730px]]
[[File:Сокол-А Analytics 15.png|center|frameless|744x744px]]
After configuring the '''survey,''' you must <u>'''save your changes'''</u>. You will then return to the main '''Sokol-A survey window'''. At this point, you can move '''the slider to the ON position''' to '''start the Sokol-A anemometer survey.'''
[[File:Analytics Sokol-A 5.png|center|frameless|736x736px]]
[[File:Analytics Sokol-A 5.png|center|frameless|736x736px]]
<blockquote>Также вы можете производить выгрузку отчета из программы Sokol Analytics.
<blockquote>You can also export a report from the [https://docs.google.com/document/d/1dXHYyUb6AepHbNffyHvMZt38uhuW1k6DUjKSh21Y-MI/edit?tab=t.0 Sokol Analytics program]. Instructions for using Sokol Analytics/exporting a report.</blockquote>


[https://docs.google.com/document/d/1dXHYyUb6AepHbNffyHvMZt38uhuW1k6DUjKSh21Y-MI/edit?tab=t.0 '''Инструкция по работе с программой Sokol Analytics/выгрузка отчета.''']</blockquote>
= '''<big>Connecting Sokol-A to third-party devices. Polling Sokol-A via Modbus.</big>''' =
To connect the '''Sokol-A''' to any '''<u>external device</u>''' other than a '''Sokol-M weather station or a Sokol-K controller,''' you must ensure that the '''external device''' is capable of:


= '''<big>Подключение Сокол-А к сторонним устройствам. Опрос Сокол-А по Modbus.</big>''' =
* Operating with an '''RS-485 interface;'''
Для подключения '''Сокол-А'''  к какому-либо '''<u>внешнему устройству,</u>''' не являющемуся метеостанцией '''Сокол-М''' или контроллером '''Сокол-К,''' необходимо удостовериться, что '''<u>внешнее устройство может:</u>'''


* Работать с интерфейсом '''RS-485;'''
* '''RS-485 specifications:'''
* Характеристики '''RS-485:'''


- Baud rate: '''19200 kbps'''
- Baud rate: 19200 kbps


- Data size: '''8'''
- Data size: 8


- Stop-bits''': 1'''
- Stop bits: 1


- Parity: '''None'''
- Parity: None


* Опрашивать устройства по протоколу '''ModBUS RTU''', обращаясь к различным сетевым адресам;
* Query devices via the '''ModBUS RTU''' protocol by addressing various network addresses;


Адрес '''Сокол-А''' '''(по умолчанию 1ый)''' можно изменить:
The '''Sokol-A address (default: 1)''' can be changed:


Основной адрес устройства можно поменять в программе '''SokolCFG.''' Для этого нужно подключить устройство к '''ПК''' посредством преобразователя интерфейсов '''RS485-USB''', в программе '''открыть СОМ порт''' преобразователя и в разделе '''Сервер''', нажав на кнопку '''“Изменить”''', установить '''новый адрес''' в правом нижнем углу.<blockquote>'''<u>''Внимание! При одновременном использовании нескольких устройств (например Сокол-А и Сокол-ТДВ) необходимо задать для них разные сетевые адреса.''</u>'''</blockquote><blockquote>'''<u>''Внимание! Программа может не отображать изменение адреса в своем интерфейсе, что не значит, что адрес не был изменен.''</u>'''</blockquote>
The device’s primary address can be changed in the '''SokolCFG program.''' To do this, connect the device to a '''PC''' using an '''RS485-USB interface converter''', open the converter’s '''COM port''' in the '''program,''' and in the '''Server section,''' click the '''“Set”''' button to set a '''new address''' in the lower-right corner.<blockquote>'''<u>''Important! When using multiple devices simultaneously (for example, Sokol-A and Sokol-TDV), you must assign different network addresses to each of them.''</u>'''</blockquote><blockquote>'''<u>''Important! The program may not display the address change in its interface, but this does not mean that the address has not been changed.''</u>'''</blockquote>
[[File:Sokol-A CFG 5.png|center|frameless|704x704px]]
[[File:Sokol-A CFG 5.png|center|frameless|704x704px]]
[[File:Sokol-A CFG 6.png|center|frameless|703x703px]]
[[File:Sokol-A CFG 6.png|center|frameless|703x703px]]


== '''<big>Пример опроса Сокол-А по Modbus</big>''' ==
== '''<big>Polling Sokol-A via Modbus example</big>''' ==
Для опроса '''Сокол-А''' необходимо запрашивать '''4 регистра.'''
To poll the '''Sokol-A''', you must request '''4 registers.'''


'''0 регистр''' - (uint16) мгновенная скорость ветра * 10 - '''<u>153 соотв. 15,3 м/с</u>'''
'''Register 0''' - (uint16) instantaneous '''wind speed''' * 10 = '''<u>153, corresponding to 15.3 m/s</u>'''


'''1 регистр''' - (uint16) мгновенное значение направление ветра  - <u>'''118 соотв. 118 град.'''</u>
'''Register 1''' - (uint16) instantaneous '''wind direction''' value - '''<u>118, corresponding to 118 degrees</u>'''


'''2 регистр''' - (uint16) средняя за 1 минуту скорость ветра * 10 - '''<u>223 соотв. 22,3 м/с</u>'''
'''Register 2''' - (uint16) '''1-minute average wind''' speed * 10 - '''<u>223, corresponding to 22.3 m/s</u>'''


'''3 регистр''' - (uint16) среднее за 1 минуту направление ветра - '''<u>327 соотв. 327 град.</u>'''
'''Register 3''' - (uint16) '''1-minute average wind direction''' - '''<u>327, corresponding to 327 degrees</u>'''




'''<u>Пример команды для Сокол-А (сетевой адрес 3):</u>'''
 
 
'''<u>Example command for Sokol-A (network address 3):</u>'''


03 03 00 00 00 04 45 EB
03 03 00 00 00 04 45 EB


03 - адрес устройства;
03 – device address;
 
03 – command type;


03 - тип команды;
00 00 – the register number starting from which the requested number of registers is read;


00 00 – номер регистра, начиная с которого запрашивается количество регистров;
00 07 - number of registers requested;


00 07 - количество запрашиваемых регистров;
45 EB - checksum with byte inversion;


45 EB - контрольная сумма с инверсией байтов;
'''<u>Пример ответа:</u>'''


'''Пример ответа:'''
Example response:


03 03 08 79 4A 00 4D 03 2A 00 4D 7F 52
03 03 08 79 4A 00 4D 03 2A 00 4D 7F 52


03  - адрес устройства;
03  - device address;


03 - тип команды;
03 - command type;


08 - количество выданных байтов;  
08 - number of bytes transmitted;  


79 4A - мгновенная скорость ветра (79 или 19065/1000=19,06 м/с)
79 4A - instantaneous wind speed (4A 79 or 19065/1000=19.06 m/s)


00 4D - мгновенное значение направление ветра (77°)
00 4D - instantaneous wind direction (77°)


03 2A - средняя за 1 минуту скорость ветра (2A03 или 10755/1000=10,7 м/с)
03 2A - 1-minute average wind speed (2A03 or 10755/1000=10.7 m/s)


00 4D - среднее за 1 минуту направление ветра (77°)
00 4D - 1-minute average wind direction (77°)


7F 52- контрольная сумма с инверсией байтов;
7F 52 - checksum with byte inversion;


= '''<big>Полезные ссылки</big>''' =
= '''<big>Useful links</big>''' =


* '''[https://drive.google.com/file/d/1rg5RttMdzh1tCcdQlvu6ZEEKc_U38TNq/view <big>Схемы подключения Сокол-А/Сокол-АН</big>]'''
* '''[https://drive.google.com/file/d/1rg5RttMdzh1tCcdQlvu6ZEEKc_U38TNq/view <big>Wiring Diagrams for Sokol-A/Sokol-AN (RUS)</big>]'''
* '''<big>[https://docs.google.com/document/d/1jJLwdr4-BIl_CgTYgZPuD5tbBpJfzkjAUboyO3MDLrI/edit?tab=t.0 Описание протокола регистров Сокол-А (Плюс АИСТ и ГРИФ)]</big>'''
* '''<big>[https://docs.google.com/document/d/1jJLwdr4-BIl_CgTYgZPuD5tbBpJfzkjAUboyO3MDLrI/edit?tab=t.0 Description of the Sokol-A Register Protocol (including AIST and GRIF) (RUS)]</big>'''  
* '''<big>[https://docs.google.com/document/d/1dXHYyUb6AepHbNffyHvMZt38uhuW1k6DUjKSh21Y-MI/edit?usp=sharing Инструкция по Sokol Analytics]</big>'''
* '''<big>[https://docs.google.com/document/d/1dXHYyUb6AepHbNffyHvMZt38uhuW1k6DUjKSh21Y-MI/edit?usp=sharing Sokol Analytics User Guide (RUS)]</big>'''

Revision as of 14:12, 14 April 2026

The current model of the Sokol-A anemorumbometer

Definition and Purpose of Sokol-A

The SOKOL-A anemorumbometer (hereinafter referred to as the Product, SOKOL-A) is designed to remotely measure instantaneous, maximum, and average airflow (wind) speeds and direction, and to transmit this data to a server (for viewing via the specialized Sokol Analytics software).

The operating principle of the sensors for the various measurement channels of the SOKOL-A anemometer is described below:

Measured parameter Principle of operation
Wind speed Based on the conversion of the airflow speed into the rotational motion of the shaft with а set of cups that is detected and measured by means of the Hall sensor
Wind/Airflow direction Based on the conversion of the wind vane's angle of rotation into an electrical signal using а magnetic rotation angle recorder (encoder)
Measured characteristics
Name of characteristic Characteristic value
Wind speed Airflow velocity measurement range, m/s from 1 to 60
Maximum permissible absolute error for airflow velocity measurements: in the range from 1 to 5 m/s; ± 0,5m/s
Permissible relative error limit for airflow velocity measurements: in the range above 5 m/s ± 10 %
Resolution, m/s 0,1
Wind/Airflow direction Airflow direction measurement range, degrees from 0 to 360
Limits of permissible absolute error in airflow direction measurements, degrees ± 3
Resolution, degrees 1

More detailed technical characteristics are presented in the technical data sheet of the device

Device construction

The SOKOL-A anemorumbometer consists of a SOKOL-A wing (1), a wind vane (2), and an anemometer (3)

(figure 1):

Assembly and Installation of the Sokol-A Anemorumbometer

Assembly of the anemometer

Assemble the anemometer in the following order: Place the skirt (3) onto the anemometer shaft (2), which is located at the top of the stand (1). There are 3 slots on the top of the skirt for attaching the anemometer cups (4). Insert the cups into the skirt, then place the cover (5) on top as shown in Figure 4 and tighten the screw (6) into the cover hole with a maximum torque of 0.5 N·m.

1) Stand

2) Shaft

3) Skirt

4) Anemometer cups

5) Cover

6) Screw

Installation of a wind vane and anemometer on the Sokol-A wing

Attach the wind vane (1) and the anemometer (2) to the wing (3) as shown in Figure 5, and secure the assembly using the nuts (4). Secure the nuts (4) with the clamps included in the mounting kit, inserting them into the hole in the wing and the nut, as shown in Figure 5a.

Installing an anemorumbometer on the mast

Mount the anemorumbometer (1) on the mast (2) as shown in Figure 6, and secure the assembly using the mounting bracket (3), washers (4), and nuts (5).


Installation diagram for the Sokol-A at the weather station placement:

Pinout, connection, configuration, operation.

Pinout Diagram for Sokol-A/Sokol-AN

The RS-485 connector pinout diagram for the Sokol-A is shown in Figure 3:


Before mounting the unit on the mast, connect the wind vane, anemometer, and RS-485 interface to the transducer as shown in Figure 8. Figure 8 shows the connection terminals, where 1 is the connector for the wind vane, 2 is the RS-485 сonnector, and 3 is the сonnector for the anemometer.


1 - Wind vane connection

2 - RS-485 connection

3 - Anemometer connection


Pinout of the extension cable for Sokol-A:

Example of the wiring diagram for the Sokol-AN version of the anemorumbometer (winter model) with a heating element:

1 - Connecting the wind vane

2 - Connecting the anemometer

3 - Connecting the RS-485

4 - Connecting the heater power supply


Pinout of the extension cable for Sokol-AN:

Connecting the anemorumbometer to the Sokol-K1 controller

The Sokol-A (1) anemometer is connected to the Sokol-K1 TEMG.469413.004 controller via the M23 TEMG.685631.003 (2) extension cable, which is included in the delivery set as shown in Figure 19. Connection to the Sokol-K1 controller enables the transmission of data collected by the anemorumbometer over a distance of up to 8 km. Connect the extension cable to the appropriate RS-485 connector on the anemorumbometer converter, route the cable through the cable coupling (3) of the computing unit (4), and connect it to the Sokol-K1 TEMG controller. 467239.004 (5) via the Sokol-A connector as shown in Figure 20.

Connection and setup via a PC.

You can connect the anemorumbometer directly to a PC. If you connect it to a PC to display wind direction and speed data, you must use Sokol Analytics or Sokol CFG. Additionally, for Sokol CFG to function properly, you must install this package of system components, as well as the appropriate driver version for your RS-485 converter, depending on the model you are using.

Bolid C2000-USB - Download link

Escort C200M converter - Download link

Escort C200M2 converter - Download link


The connection diagram for the Sokol-A to a PC is shown in Figures 10a and 10b. (The Escort C200-M2 converter (4) must be purchased separately for the connection shown in Figure 10a.)

Sokol-A + Sokol CFG

Install the Sokol CFG software as follows:

− download the Sokol CFG software;

− Run the setup_Sokol CFG.exe file;

− Follow the on-screen instructions during installation;

− Launch the Sokol CFG software.


In the standalone software window, select the COM port to which the Sokol-A anemorumbometer is connected.

If the port is not listed, follow these steps:

− Open Device Manager on your computer;

− In the Ports (COM and LPT) section, open the properties of the STMicroelectronics Virtual COM Port (C200M) or USB-SERIAL CH341A (C200M2) virtual COM port (if there are no devices with these names in the list, check that the driver for your converter is installed);

Manually set the port number within the range COM2–COM10;

Restart the anemorumbometer by reconnecting the transducer’s USB cable to the PC; − Reopen the Sokol CFG program and select the configured COM port; − Click the “Open Port” button.


Once successfully connected to the software, the "Sensors" tab will display readings from the anemometer. These include key meteorological parameters: wind direction and wind speed.


The serial number and software version are displayed on the left.


The "Server" tab displays the Modbus network address of the anemorumbometer (Modbus field).

Sokol-A + Sokol Analytics

To use the standalone Sokol Analytics software, follow these steps:

Download the Sokol Analytics software;

− Run the sokolanalytics_262c.exe file;

− Follow the on-screen instructions during installation. Launch the Sokol Analytics software, and a window will open.


In this window, click the "Connect" button and enable polling for the Sokol-A device.



Next, the Sokol-A device polling window will open. You will need to configure the polling settings.

- Select the correct COM port assigned to your converter.

- Set the required network address for polling the Sokol-A. The Sokol-A network address can be set, changed, or checked in the Sokol CFG program. By default, the Sokol-A anemometer is set to network address 1.

- Set the required polling interval.

- Enable/disable the automatic launch of the survey when Sokol Analytics starts.


Important! After changing the network address on the "Sokol-A" anemometer in the Sokol CFG program, the displayed network address may not update, but the change will take effect.

After configuring the survey, you must save your changes. You will then return to the main Sokol-A survey window. At this point, you can move the slider to the ON position to start the Sokol-A anemometer survey.

You can also export a report from the Sokol Analytics program. Instructions for using Sokol Analytics/exporting a report.

Connecting Sokol-A to third-party devices. Polling Sokol-A via Modbus.

To connect the Sokol-A to any external device other than a Sokol-M weather station or a Sokol-K controller, you must ensure that the external device is capable of:

  • Operating with an RS-485 interface;
  • RS-485 specifications:

- Baud rate: 19200 kbps

- Data size: 8

- Stop bits: 1

- Parity: None

  • Query devices via the ModBUS RTU protocol by addressing various network addresses;

The Sokol-A address (default: 1) can be changed:

The device’s primary address can be changed in the SokolCFG program. To do this, connect the device to a PC using an RS485-USB interface converter, open the converter’s COM port in the program, and in the Server section, click the “Set” button to set a new address in the lower-right corner.

Important! When using multiple devices simultaneously (for example, Sokol-A and Sokol-TDV), you must assign different network addresses to each of them.

Important! The program may not display the address change in its interface, but this does not mean that the address has not been changed.

Polling Sokol-A via Modbus example

To poll the Sokol-A, you must request 4 registers.

Register 0 - (uint16) instantaneous wind speed * 10 = 153, corresponding to 15.3 m/s

Register 1 - (uint16) instantaneous wind direction value - 118, corresponding to 118 degrees

Register 2 - (uint16) 1-minute average wind speed * 10 - 223, corresponding to 22.3 m/s

Register 3 - (uint16) 1-minute average wind direction - 327, corresponding to 327 degrees



Example command for Sokol-A (network address 3):

03 03 00 00 00 04 45 EB

03 – device address;

03 – command type;

00 00 – the register number starting from which the requested number of registers is read;

00 07 - number of registers requested;

45 EB - checksum with byte inversion;

Пример ответа:

Example response:

03 03 08 79 4A 00 4D 03 2A 00 4D 7F 52

03  - device address;

03 - command type;

08 - number of bytes transmitted;  

79 4A - instantaneous wind speed (4A 79 or 19065/1000=19.06 m/s)

00 4D - instantaneous wind direction (77°)

03 2A - 1-minute average wind speed (2A03 or 10755/1000=10.7 m/s)

00 4D - 1-minute average wind direction (77°)

7F 52 - checksum with byte inversion;