→Connection to the sensor, setup, calibration and calibration via a mobile application on Android
(→Connection to the sensor, setup, calibration and calibration via a mobile application on Android) |
|||
| Line 273: | Line 273: | ||
'''If possible, we recommend calibration with fuel. If tank calibration is not planned or is impossible, then calibration with fuel is a mandatory procedure.''' | '''If possible, we recommend calibration with fuel. If tank calibration is not planned or is impossible, then calibration with fuel is a mandatory procedure.''' | ||
== '''<big>How to change the voltage range in the analog output</big>''' == | |||
If you need to connect the sensor to a tracker using analog output and adjust the voltage range (minimum and maximum values) for compatibility, you can do so in the "'''Settings'''" menu. There, you can enter the minimum and maximum voltage values ('''1''') within the range of 0.2 V to 20 V, and then press the "'''Install'''" button ('''2''') to apply the changes. | |||
For example, if your microcontroller's analog input can only accept a voltage range of 3 V to 7 V, you can adjust the minimum and maximum thresholds of the TD-150-BLE’s analog output accordingly to ensure compatibility between the devices. | |||
[[File:TD-150 BLE analog calibraiton.jpg|frameless]] [[File:TD-150 BLE analog calibraiton selector.jpg|frameless]] | |||
== '''<big>Setting the mode, range and network address</big>''' == | == '''<big>Setting the mode, range and network address</big>''' == | ||