DU-BLE: Difference between revisions
→Vertical rotation control
| (7 intermediate revisions by 2 users not shown) | |||
| Line 178: | Line 178: | ||
2) '''Speed and rpm'''. The sensor will transmit the number of complete revolutions and the rotation speed in rpm. The rotation speed will be calculated by the sensor after the first three full revolutions. The speed will be positive in one direction, negative in the other. You can learn more about how to set up speed recognition on the monitoring platform in [https://docs.google.com/document/d/13xV8zCP8JVlJ-dzKR4HQJ8sr28X-L5w_0APE2Nq293E/edit?usp=sharing this manual] | 2) '''Speed and rpm'''. The sensor will transmit the number of complete revolutions and the rotation speed in rpm. The rotation speed will be calculated by the sensor after the first three full revolutions. The speed will be positive in one direction, negative in the other. You can learn more about how to set up speed recognition on the monitoring platform in [https://docs.google.com/document/d/13xV8zCP8JVlJ-dzKR4HQJ8sr28X-L5w_0APE2Nq293E/edit?usp=sharing this manual] | ||
[[File:F0cc0683-1aae-4b82-be4f-aa5230b8e6ce.png|948x948px]] | |||
[[File:Vertical rotation control diagram.png]] | [[File:Vertical rotation control diagram.png]] | ||
| Line 316: | Line 319: | ||
'''Single-axis mode''': measures the rotation angle along the X axis (roll) in the horizontal position, i.e. the ZY plane is perpendicular to the installation plane. It is possible to set zero. The measurement range is 360°. There is no trigger event. | '''Single-axis mode''': measures the rotation angle along the X axis (roll) in the horizontal position, i.e. the ZY plane is perpendicular to the installation plane. It is possible to set zero. The measurement range is 360°. There is no trigger event. | ||
'''Dual-axis mode''': measures the rotation angle along the Y axis (roll) and the rotation angle along the X axis (pitch) in the horizontal position. It is possible to set zero. The measurement range is 180°. There is no trigger event.<blockquote><big>'''Data transfer in | '''Dual-axis mode''': measures the rotation angle along the Y axis (roll) and the rotation angle along the X axis (pitch) in the horizontal position. It is possible to set zero. The measurement range is 180°. There is no trigger event.<blockquote><big>'''Data transfer in Horizontal inclinometer mode is supported only when using [[BA-BLE]]'''</big></blockquote>[[File:Horizontal inclinometer diagram.png]] | ||
== '''<big>Vertical inclinometer</big>''' == | == '''<big>Vertical inclinometer</big>''' == | ||
| Line 327: | Line 330: | ||
'''Single-axis mode''': measures the rotation angle along the X axis (roll) in the horizontal position, i.e. the ZY plane is perpendicular to the installation plane. It is possible to set zero. The measurement range is 360°. There is no trigger event. | '''Single-axis mode''': measures the rotation angle along the X axis (roll) in the horizontal position, i.e. the ZY plane is perpendicular to the installation plane. It is possible to set zero. The measurement range is 360°. There is no trigger event. | ||
'''Dual-axis mode''': measures the rotation angle along the Y axis (roll) and the rotation angle along the X axis (pitch) in the horizontal position. It is possible to set zero. The measurement range is 180°. There is no trigger event.<blockquote><big>'''Data transfer in | '''Dual-axis mode''': measures the rotation angle along the Y axis (roll) and the rotation angle along the X axis (pitch) in the horizontal position. It is possible to set zero. The measurement range is 180°. There is no trigger event.<blockquote><big>'''Data transfer in Vertical inclinometer mode is supported only when using [[BA-BLE]]'''</big></blockquote>[[File:Vertical inclinometer diagram.png]] | ||
= <big>'''Sealing and installation'''</big> = | |||
== '''<big>Connection dimensions</big>''' == | |||
=== '''<big>Connection dimensions of the DU-BLE of the former design</big>''' === | |||
[[File:Connection dimensions DU-BLE former design .png]] | |||
[[File:Dimensions of former design DU-BLE.png]] | |||
=== '''<big>Connection dimensions of the DU-BLE of the current design</big>''' === | |||
[[File:Connection dimensions DU-BLE current design .png]] | |||
[[File:Dimensions of current design DU-BLE.png]] | |||
== ''' | == <big>'''Sensor sealing'''</big> == | ||
=== ''' | === <big>'''Sealing DU-BLE of the former design'''</big> === | ||
To seal the sensor and prevent unauthorized access to it, install the protective cover and pass the seal through the special holes in the cover. Tighten the seal against its end into the special hole in the seal. Cut off the excess wire of the seal. | |||
[[ | [[File:Sealing former design DU-BLE.png]] | ||
=== '''<big> | === <big>'''Sealing DU-BLE of the current design'''</big> === | ||
[[ | You will need the sensor protective cover and the seal provided in the kit<gallery widths="300" heights="300"> | ||
File:New_design_cap.png|'''<big>Protective cover DU-BLE</big>''' | |||
File:New_design_seal.png|'''<big>DU-BLE seal</big>''' | |||
</gallery>The cover is attached to the sensor head | |||
[[File:TD-BLE_with_cap.png|none|thumb|455x455px|'''<big>DU-BLE with cap</big>''']] | |||
== <big>''' | Then the seal itself is fixed in a special hole (it must be inserted to the end, with the '''closed end facing outward''')<gallery widths="350" heights="350"> | ||
File:Installing_TD-BLE_seal.png|'''<big>Installing DU-BLE seal</big>''' | |||
File:Installed_TD-BLE_seal.png|'''<big>Installed DU-BLE seal</big>''' | |||
</gallery>To remove the seal, screw in the special key from the kit (you can also use any self-tapping screw of suitable size) and pull it towards yourself. | |||
[[File:Removing_seal.png|none|thumb|493x493px|'''<big>Removing seal</big>''']] | |||
[[File:Seal_after_removal.png|none|thumb|'''<big>Seal after removal</big>''']] | |||
This makes it impossible to remove the seal without damaging it. This provides additional protection against unauthorized access. | |||
=== <big> | === '''<big>Alternative sealing for DU-BLE of the current design</big>''' === | ||
Also included with the current DU-BLE is an alternative seal if a numbered seal is required. | |||
* The wire must be threaded through the hole in the sensor cover | |||
[[File:Alternative_sealing_step_1.png|frameless|433x433px]] | |||
* Thread both ends of the cable through the hole in the sensor head | |||
[[File:Alternative_sealing_step_2.png|frameless|519x519px]] | |||
* | * Pass both ends through the seal, tighten the cable and install the seal by pressing the protruding part of the seal | ||
[[ | [[File:Alternative_sealing_step_3.png|frameless|543x543px]] | ||
== <big>'''Mounting and direction'''</big> == | |||
The most common mounting method is self-tapping screws with a sealing washer. It is also possible to install on threaded crimp nuts, welded bushings and other structural elements. The sensor can be mounted on pre-prepared places using screws and bolts with strength class not less than 4.8. It is necessary to ensure tightness of the connection between the sensor body and the tank. For additional protection it is allowed to use automotive oil and gasoline resistant sealant. | |||
For plastic tanks rivets and bolts can be used. | |||
[[File:Antenna_direction.png|frameless|768x768px]] | |||
== <big>'''How hard to screw in self-tapping screws'''</big> == | |||
== | == [[File:How_to_hard_to_tighten_the_screws.png|frameless|512x512px]] == | ||
= '''<big>Firmware update (FW)</big>''' = | |||
[[File:DU-BLE update.gif]] | |||
To update the firmware on the DU-BLE: | |||
[[ | * Download the current firmware version as a file to the phone memory | ||
* Connect to the sensor | |||
* Go to “'''Additional Features'''” | |||
[[File:Additional features DU-BLE.png|546x546px]] | |||
* Go to FW update | |||
[[ | [[File:FW update menu.png|577x577px]] | ||
* Select the firmware file ('''1''') from the phone memory (The firmware file is the .zip archive itself, no need to unzip it) and start the flashing process ('''2'''). '''These actions should be performed within 30 seconds after entering update mode!''' | |||
[[ | [[File:Start_of_TD-BLE_update.png|frameless|732x732px]] | ||
* The flashing process should start. '''Do not close or minimize the application during the flashing process!''' | |||
[[File:TD-BLE_update_process.jpg|frameless|728x728px]] | |||
* When the updating is completed, a window will pop up indicating that the update was successful | |||
[[File:The_TD-BLE_update_has_been_completed.jpg|frameless|741x741px]] | |||
Firmware update via the IOS mobile application is shown in [https://youtu.be/rPsI1AdrTQs this video] | |||
Up-to-date firmware can be found in the [https://www.fmeter.ru/en/download/?product=DUBLE#escort-duble Download materials] | |||
The firmware file is the .zip archive itself, no need to unzip. | |||
= '''<big> | = '''<big>Useful links</big>''' = | ||
* '''<big>[https://www.fmeter.ru/download/_ftp/datchik-ugla-naklona/eskort-du-ble/ | * '''<big>[https://www.fmeter.ru/download/_ftp/eng/datchik-ugla-naklona/eskort-du-ble/Escort%20DU-BLE%20datasheet.pdf?v=071220114144 Technical data sheet of the device]</big>''' | ||
* '''<big>[https://www.fmeter.ru/produktsiya/besprovodnoy-datchik-ugla-naklona/eskort-du-ble/#active | * '''<big>[https://www.fmeter.ru/en/produktsiya/besprovodnoy-datchik-ugla-naklona/eskort-du-ble/#active Product page]</big>''' | ||
* '''<big>[https://www.fmeter.ru/download/?product=DUBLE#escort-duble | * '''<big>[https://www.fmeter.ru/en/download/?product=DUBLE#escort-duble Download materials]</big>''' | ||
* '''<big>[[ | * '''<big>[[Table of compatibility of BLE sensors with trackers and other devices]]</big>''' | ||
* [https://docs.google.com/document/d/ | * '''<big>[https://docs.google.com/document/d/13xV8zCP8JVlJ-dzKR4HQJ8sr28X-L5w_0APE2Nq293E/edit?usp=sharing Setting up the received readings on the platform]</big>''' | ||