= '''<big>Definition and purpose of the sensor</big>''' =
= '''<big>Definition and purpose of the sensor</big>''' =
[[RU:ALS| Русская версия]]
[[File:Current design of ALS.jpg|thumb|[https://wikiru.fmeter.ru/images/thumb/8/8d/%D0%A2%D0%B5%D0%BA%D1%83%D1%89%D0%B8%D0%B9_%D0%B4%D0%B8%D0%B7%D0%B0%D0%B9%D0%BD_ALS.jpg/723px-%D0%A2%D0%B5%D0%BA%D1%83%D1%89%D0%B8%D0%B9_%D0%B4%D0%B8%D0%B7%D0%B0%D0%B9%D0%BD_ALS.jpg?20241218111713 '''<big>Current design of ALS</big>''']]]
[[File:Current design of ALS.jpg|thumb|[https://wikiru.fmeter.ru/images/thumb/8/8d/%D0%A2%D0%B5%D0%BA%D1%83%D1%89%D0%B8%D0%B9_%D0%B4%D0%B8%D0%B7%D0%B0%D0%B9%D0%BD_ALS.jpg/723px-%D0%A2%D0%B5%D0%BA%D1%83%D1%89%D0%B8%D0%B9_%D0%B4%D0%B8%D0%B7%D0%B0%D0%B9%D0%BD_ALS.jpg?20241218111713 '''<big>Current design of ALS</big>''']]]
Escort's high-precision water level sensors ("WLS" or "ALS", also referred to as "gauges" or "sensors") are designed to determine the fill level of water in containers, tanks, and storage vessels. The ALS gauge is used in specialized equipment as a water level indicator and in industry as a level sensor for liquids with properties similar to water. The measurement principle of Escort's WLS is capacitive, relying on the dielectric permittivity of the medium; in this case, it measures the level of non-aggressive liquids such as water, aqueous solutions, liquid fertilizers, etc. Materials in contact with the measured liquid include aluminum alloy (AD-31) and polyacetal (PA-6).
Escort's high-precision water level sensors ("WLS" or "ALS", also referred to as "gauges" or "sensors") are designed to determine the fill level of water in containers, tanks, and storage vessels. The ALS gauge is used in specialized equipment as a water level indicator and in industry as a level sensor for liquids with properties similar to water. The measurement principle of Escort's WLS is capacitive, relying on the dielectric permittivity of the medium; in this case, it measures the level of non-aggressive liquids such as water, aqueous solutions, liquid fertilizers, etc. Materials in contact with the measured liquid include aluminum alloy (AD-31) and polyacetal (PA-6).
Line 129: Line 130:


'''After cutting the sensor tubes, use the special insulating heat shrink cap included with the sensor for insulating the inner tube. Use a heat gun or any other heating element to shrink the cap properly.'''
'''After cutting the sensor tubes, use the special insulating heat shrink cap included with the sensor for insulating the inner tube. Use a heat gun or any other heating element to shrink the cap properly.'''
Example:
'''Take this plastic insulation cap'''
[[File:Photo 2022-10-24 14-24-42.jpg|990x990px]]
'''Cover the inner tube with this cap'''
[[File:Photo 2022-10-24 14-24-42 (2).jpg|993x993px]]
'''Press down on cover cap'''
[[File:Photo 2022-10-24 14-19-54.jpg|992x992px]]
'''Use hot air gun to finish the insultion'''
[[File:Https s3.eu-central-1.wasabisys.comincoming-chat-api20221024861320276a824-1f9f-4c3c-a37c-3a1a00e28910.jpg|1000x1000px]]


The extension of the water level sensor tubes is not allowed due to the design features of the inner tube.
The extension of the water level sensor tubes is not allowed due to the design features of the inner tube.
Line 335: Line 361:
You should clean the sensor tubes—preferably by blowing them out through the drainage holes using compressed air.
You should clean the sensor tubes—preferably by blowing them out through the drainage holes using compressed air.


If this error occurred after the sensor was put into operation, it is highly likely that contaminants entered the tubes from the reservoir. In this case, it is also necessary to clean the reservoir thoroughly.
If this error occurred after the start of operation of the sensor, it means that most likely these impurities got into the sensor tubes from the container and in this case it is also needed to ensure that the tank itself doesn't contain any contaminations. Clean the container, if necessary. Note that an ALS installed outside a contaminated container may function correctly, but the same sensor installed in such container may generate this error code.


== '''<big>Level 6500</big>''' ==
== '''<big>Level 6500</big>''' ==